background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 

Configuring Radiant POS terminals 

10 

Configuring the P1220 POS terminal 

Follow these steps to configure a P1220 POS terminal for use with CounterPoint: 

1.  If you are using any of the following external devices with your P1220, connect them 

to the following ports: 

Device 

Radiant Part # 

Port 

Printer-driven cash drawer  
(16” or 18.8”) 

P000F024 

or

 

P000F031 

DK 

(on Epson TM-T88)

 

Epson TM-T88 series receipt printer 
(RS232 interface) 

P201F019 

or

 

P201F039 

Serial 1 

2x20 display (pole mount) 

P703F001 

Serial 2 

Serial modem 

N/A 

USB 

(with USB to serial adapter)

 

NOTE:

  If you are using a serial modem with your P1220, follow the instructions included 

with your USB to serial adapter to connect the modem to an available USB port. 

2.  Browse to your top-level directory (e.g., 

C:\SYN

) and double-click the 

SYNRUN.SYN

 file 

to open it in Notepad or another text editor. 

3.  Add the following lines to 

SYNRUN.SYN

CPSIO1=C 
SYNCOM1=98n1 

4.  If you are not running CounterPoint over Terminal Services and you are using an 

external (i.e., pole mount) 2x20 display, add the following line to 

SYNRUN.SYN

CPSIO2=W 

5.  If you are not running CounterPoint over Terminal Services and you are using the 

P1220’s built-in (i.e., POS mount) 2x20 display, add the following line to 

SYNRUN.SYN

CPSIO5=W 

6.  Save the modified 

SYNRUN.SYN

 file, and then close your text editor. 

7. Copy 

the 

CP1220Mode.bat

 and 

OPOSim.exe

 files from your top-level directory to the 

Windows 

Startup

 directory for all users (i.e., 

C:\Documents and Settings\All Users\Start 

Menu\Programs\Startup

). 

8. Double-click 

OPOSim.exe

 in the 

Startup

 directory to start the OPOS Input Manager. 

9. Right-click 

the 

OPOS Input Manager

 icon (

) in the Windows 

system tray and select 

Options

 to display the 

OPOS Input 

Manager

 window. 

10. Select 

RSMsr

 from the 

MSR

 list, and then select the 

Track

 

you want to read. 

NOTE: 

If you are processing debit cards, select track 

2

11. Select the 

Auto-enable on start-up

 check box, and then click 

the 

Enable

 button. 

12. Close the 

OPOS Input Manager

 window. 

13. Select 

Settings / Printers and Faxes

 from the 

Start

 menu, right-click the 

Epson TM-T88 - 

Serial

 printer, and then click 

Properties

Summary of Contents for P1550

Page 1: ...int Installation Guide to install CounterPoint and configure each Radiant POS terminal as a CounterPoint workstation NOTE If you are running CounterPoint over Windows Terminal Services you will config...

Page 2: ...display settings Configure Remote Desktop Connection settings Follow these steps to configure the Remote Desktop Connection settings on each of your Radiant POS terminals 1 From one of your POS termin...

Page 3: ...r the necessary dll files regansi Configure 2x20 display settings Follow these steps to allow the 2x20 displays connected to your POS terminals to function over Terminal Services 1 On your CounterPoin...

Page 4: ...in Notepad or another text editor 3 Add the following lines to SYNRUN SYN CPSIO1 C SYNCOM1 98n1 4 If you are not running CounterPoint over Terminal Services add the following line to SYNRUN SYN CPSIO2...

Page 5: ...en press Enter to load the pre defined device codes for Radiant POS terminals 17 When the pre defined data is updated press ESC to return to the main menu 18 Select Setup Point of Sale Registers speci...

Page 6: ...n menu 24 Select Setup Point of Sale Drawers specify a Drawer number and Register number for the POS terminal s cash drawer and then enter a Description for the drawer 25 Enter 1550 in the Drawer devi...

Page 7: ...re not running CounterPoint over Terminal Services add the following line to SYNRUN SYN CPSIO4 W 5 Save the modified SYNRUN SYN file and then close your text editor 6 Copy the CP1550Mode bat and OPOSi...

Page 8: ...y device and then enter COM4 in the corresponding Device ID field 17 Press Enter at the Field number to change prompt to save your changes and then press ESC to close the Registers screen and return t...

Page 9: ...code field for the Card reader device and enter COM5 in the corresponding Device ID field Configuring the P1520 keyboard transparent MSR If you are setting up a P1520 POS terminal with a keyboard tra...

Page 10: ...al Services and you are using an external i e pole mount 2x20 display add the following line to SYNRUN SYN CPSIO2 W 5 If you are not running CounterPoint over Terminal Services and you are using the P...

Page 11: ...odes for Radiant POS terminals 18 When the pre defined data is updated press ESC to return to the main menu 19 Select Setup Point of Sale Registers specify a Register number for your POS terminal and...

Page 12: ...ESC to close the Registers screen and return to the main menu 25 Select Setup Point of Sale Drawers specify a Drawer number and Register number for the POS terminal s cash drawer and then enter a Desc...

Reviews: