54
R1C 24 /B - RAD - ING - Manuale - 2007.1_SK.3_MIAB3013_R7_VK42_B3
2 Co
dic
i di seg
na
la
zio
ne
anomalie
_
co
mbinat
a_
MI
A
B
30
13
_
E
N
2. MAINTENANCE
SUPPOR
T
CENTRE
CODE
FAULT
POSSIBLE CAUSE
SOLUTION
RESET
E16
ELECTRIC FAN
ELECTRIC FAN BOARD
BROKEN;
REPLACE IT;
AUTOMATIC.
ELECTRIC FAN BROKEN;
REPLACE IT;
FAULTY POWER SUPPLY
CABLE.
REPLACE IT.
E22
P A R A M E T E R S
PROGRAMMING REQUEST
MICRO=PROCESSOR
MEMORY LOSS.
PARAMETERS REPROGRAMMING.
MANUAL
RESET
(CUT OFF THE
TENSION).
E31
REMOTE CONTROLLER
INCOMPATIBLE
INDICATES THAT THE
REMOTE CONTROLLER
CONNECTED TO
THE BOILER IS NOT
COMPATIBLE WITH THE
CIRCUIT BOARD
REPLACE IT WITH A COMPATIBLE
MODEL.
AUTOMATIC.
E98
SUPPLY VOLTAGE
SUPPLY VOLTAGE OFF THE
OPERATION RANGE (
d
160
VOLTS).
CHECK THE POWER SUPPLY
NETWORK (THE ERROR DEACTIVATES
AUTOMATICALLY AS SOON AS THE
SUPPLY VOLTAGE FALLS BACK WITHIN
THE REQUESTED LIMITS).
AUTOMATIC.
E99
GENERAL INTERNAL
BOARD ERROR
INCORRECT SIGNAL
RECOGNITION BY THE
MODULATION BOARD
MICRO-PROCESSOR.
IF THE MODULATION BOARD DOES NOT
RESET THE ERROR AUTOMATICALLY,
REPLACE IT.
AUTOMATIC.