R1K 34 - RAD - ING - Man.Ut. - 1901.1_firm.L224C_AHS

3 Ac

censione_Modalità 

di funzionamento_Antigel

o_MIAH4_MIAH6_EN

3. USE  

USER

pump anti-locking and diverter valve anti-locking 
systems still remain active.

To switch the boiler to OFF operating mode, press 
the function key ‘

’, the symbol ‘

’ will 

appear fixed on the display, indicating that the 
function is enabled (for non condensing models 
will appear the message ‘OFF’).

If the boiler was previously running, it will be turned 
off and the post-ventilation and post-circulation 
functions will be enabled.

If you have to deactivate the boiler for a long period 
of time, proceed as follows:

 

› contact the Technical support centre that will 

empty the water system, where no anti-freeze is 
intended, and will cut off the power, water and 
gas supply.

 

› Or leave the boiler in OFF operating mode 

keeping active the electrical and gas supplies so 
that the anti-freeze function may activate.

1.1.7. INFORMATIONAL NOTE ON 

ANTI-FREEZE FUNCTION 

The boiler is protected against freezing thanks to 
the electronic board preparation with functions 
that start the burner and heat the concerned parts 
when their temperature goes below the minimum 
pre-set values.

 WARNING

This function is available only if:

 

› the boiler is powered; 

 

› the gas supply is open;

 

› the pressure of the system is proper;

 

› the boiler is not blocked.

Summary of Contents for R1K 34

Page 1: ...R1K 34 RAD ING Man Ut 1901 1_firm L224C_AHS Use Manual for model Premix condensing system boiler only heating R1K 34...

Page 2: ..._EN Contact Details Office Address 10 Frankston Gardens Drive Carrum Downs Victoria Australia 3201 Email Address sales hydronicsupplies com au Website www hydronicsupplies com au Phone 61 3 9708 2600...

Page 3: ...E WARNINGS 6 1 1 2 CONTROL PANEL 7 1 1 3 DISPLAY ICONS 8 1 1 4 INFO MENU DISPLAY DATA 9 1 1 5 START UP 10 1 1 6 OPERATING MODE 10 1 1 7 INFORMATIONAL NOTE ON ANTI FREEZE FUNCTION 11 1 1 8 SYSTEM FILLI...

Page 4: ...4 R1K 34 RAD ING Man Ut 1901 1_firm L224C_AHS R1K 34_Man Ut _AHS_EN TABLE OF CONTENTS...

Page 5: ...are addressed to all those who will use the machine The machine must be used and accessed only by qualified operators that fully read and understood the User section paying particular attention to th...

Page 6: ...rty due to incorrect use DANGER The boiler should not be used by persons including children with reduced physical sensory or mental capacities or without suitable knowledge or experience unless they a...

Page 7: ...URES AND OTHER INFORMATION see chapter INFO MENU DISPLAY HOLD FOR 5 SECONDS IN OFF OPERATING MODE TO VIEW THE LAST 5 FAULTS 3 OPERATING MODE SELECTION KEY ONLY HEATING OFF 4 RESET KEY FAULTS RESET CHI...

Page 8: ...PER TEMPERATURE DISPLAY d7 6 EXTERNAL PROBE INSTALLED EXTERNAL PROBE TEMPERATURE d1 7 TEMPERATURE DISPLAY SET POINT PARAMETER VALUE 8 OPEN THERM COMMUNICATION PRESENT REMOTE CONTROL AREA CONTROL UNIT...

Page 9: ...RETURN PROBE TEMPERATURE d5 SOLAR COLLECTOR TEMPERATURE IF SOLAR BOARD INSTALLED SCS d6 SOLAR BOILER TEMPERATURE BOTTOM IF SOLAR BOARD INSTALLED SBSI d7 SOLAR BOILER TEMPERATURE TOP IF SOLAR BOARD IN...

Page 10: ...enabled Whenever heating energy is needed to heat the rooms the automatic start up system will start the burner this is indicated by displaying the symbol blinking WINTER MODE In this mode the boiler...

Page 11: ...ctivate the boiler for a long period of time proceed as follows contact the Technical support centre that will empty the water system where no anti freeze is intended and will cut off the power water...

Page 12: ...using pressure gauge M fig 1 that the system pressure reaches 1 2 bar see fig 2 After performing this operation make sure that the loading tap R fig 1 is properly closed After the water pressure reset...

Page 13: ...AFETY THERMOSTAT 95 C CONTACT THE TECHNICAL SUPPORT CENTRE E03 FUMES SAFETY THERMOFUSE 102 C CONTACT THE TECHNICAL SUPPORT CENTRE E04 WATER MISSING IN THE SYSTEM IF THE SYSTEM PRESSURE IS BELOW 1 2 BA...

Page 14: ...ONTACT THE TECHNICAL SUPPORT CENTRE E31 INCOMPATIBLE REMOTE CONTROL CONTACT THE TECHNICAL SUPPORT CENTRE E32 COMMUNICATION ERROR BETWEEN THE BOILER BOARD AND THE MODBUS BOARD CONTACT THE TECHNICAL SUP...

Page 15: ...funzioni attive_solo risc_MIAH4_EN 3 USE USER 1 1 10 ACTIVE FUNCTIONS SIGNALLING CODES CODE FUNCTION INTERVENTION F08 HEATING ANTI FREEZE FUNCTION ACTIVE WAIT UNTIL THE OPERATION IS COMPLETED F33 SYS...

Page 16: ...the device using a wet cloth and come neutral soap WARNING DONOTuseabrasiveorpowderdetergents as they might damage the plastic cover and control elements 1 1 13 DISPOSAL The boiler and all its accesso...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...RADIANT BRUCIATORI s p a Via Pantanelli 164 166 61025 Loc Montelabbate PU Tel 39 0721 9079 1 fax 39 0721 9079279 e mail info radiant Internet http www radiant it...

Reviews: