2. MAINTENANCE
SUPPOR
T CENTER
2.2. MAINTENANCE
2.2.7. GENERAL MAINTENANCE
WARNINGS
ATTENTION
All maintenance operations must be
performed by qualified staff and authorized by
RADIANT BRUCIATORI spa.
WARNING
The maintenance operations must be
performed once every twelve months starting from
the boiler installation date.
WARNING
To ensure longer life span and proper
operation of the device, during the maintenance
operations use only original spare parts.
DANGER
Before each components cleaning or
replacement operation, ALWAYS cut off the POWER,
WATER and GAS supply of the boiler.
Please perform the following operations once a year:
› check the sealing of the gas components, and
replace the gaskets if necessary;
› check the sealing of the water components, and
replace the gaskets if necessary;
› visually check the flame and the condition of the
combustion chamber;
› if necessary make sure that the combustion is
adjusted correctly and if required proceed as
indicated in section 2.1.3 “CO2 VALUE CHECK AND
CALIBRATION”;
› remove and clean the burner from oxidation;
› check the integrity and the position of the sealed
chamber sealing gasket;
› check the primary exchanger, if necessary, clean
it;
› check the operation of the gas burner start up
and safety systems. If necessary, remove and
clean the flame detection and start up electrodes
from incrustations paying attention to respect the
distances with respect to the burner;
› check the heating circuit safety systems: limit
temperature safety thermostat; limit pressure
safety;
› check the pre-load pressure of the expansion tank;
› make sure that the permanent ventilation outlets
are present, correctly sized and functioning, based
on the installed devices. Follow the requirements
provided by Local and National legislation;
› periodically check the integrity of the venting
system for safety and proper operation;
› check that the wiring is installed in compliance with
the requirements in the boiler instruction manual;
› check the wiring inside the control panel;
› check the flow and temperature of domestic hot
water;
› check the proper operation of the condensate
draining system, including the devices outside
the boiler such as condensate collection
devices installed along the path of the venting or
neutralization devices for acid condensate.
› check that the liquid flow is not obstructed and
that there is on combustion gas build up inside the
internal system.
Summary of Contents for R1K 34
Page 6: ......
Page 62: ......
Page 65: ...65 R1K 34 B RAD ING Manuale 1512 2_CSA_TTS 3 USE USER...
Page 66: ...66 R1K 34 B RAD ING Manuale 1512 2_CSA_TTS 3 USE USER...
Page 67: ...67 R1K 34 B RAD ING Manuale 1512 2_CSA_TTS 3 USE USER...
Page 68: ...68 R1K 34 B RAD ING Manuale 1512 2_CSA_TTS 3 USE USER...
Page 79: ......