13
R1K 50 RAIN - RAD - ING - Man.Inst. - 1901.1_SK.3_firm.L224C_AHS
1 Ins
tallazione gener
ator
e_R1K 50 RAIN_EN
2. INSTALLATION
INST
ALLER
1.1.8. BOILER INSTALLATION
MINIMAL TECHNICAL SPACES
In order to allow the access inside the boiler for
maintenance operations, you have to respect the
minimum technical spaces indicated in figure 1.
WARNING
The incorrect slopes of the device can
cause the incorrect discharge of condensate by
means of the discharge duct with consequent
condensate stagnation inside the condensate
module.
WARNING
The boiler must be installed only on a
vertical solid wall, able to sustain its weight.
WARNING
The boilers have the electrical protection
degree IPX5D. The outdoor installation in partially
protected environments (platform roof, balcony -
see fig. 2) is allowed in compliance with the related
standards. The Company is not held liable for
installations in environments with a temperature
under –10°C or non-compliant with the above
indications.
H
A
X
Y
B
A
A
A - 200 mm
B -
500
mm
X -
200
mm
Y -
200
mm
H - 1,000 mm
fig.1
fig. 2
1,200 mm minimum
SECTION A-A
balcony/
platform roof