45
R1KR 34 - RAD - ING - Manual - 1807.1_SK.2_MIAB3013_R7_PDX
2
D
a
ti t
e
cn
ic
i_R
1
K
R
34
_E
R
P
_E
N
1
5
5
0
2
_P
D
X
_E
N
2. MAINTENANCE
SUPPOR
T
C
ENTRE
Heating Min. fan speed - G31
Hz
45
D.H.W Min. fan speed - G31
Hz
45
Fuel consumption - G31
kg/h
2,64
Technical parameters for boiler space heaters, boiler combination heaters and cogeneration
space heaters
Model
R1KR 34
Condensing boiler
[yes/no]
yes
Low-temperature (**) boiler:
[yes/no]
no
B11 boiler
[yes/no]
no
Cogeneration space heater
[yes/no]
no
If yes, equipped with a supplementary heater
[yes/no]
no
Combination heater
[yes/no]
yes
Rated heat output Prated
kW
33,35
For boiler space heaters and boiler combination
heaters: Useful heat output
At rated heat output and high-temperature regime (*) P
4
kW
33,35
At 30 % of rated heat output and low-temperature regime (**)
P
1
kW
10,20
For cogeneration space heaters: Useful heat output
At rated heat output of cogeneration space heater with
supplementary heater disabled P
Sup0
kW
-
At rated heat output of cogeneration space heater with
supplementary heater enabled P
Sup100
kW
-
)RUFRJHQHUDWLRQVSDFHKHDWHUV(OHFWULFDOHႈFLHQF\
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUGLVDEOHGȘ
el,Sup0
%
-
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUHQDEOHGȘ
el,Sup100
%
-
$X[LOLDU\HOHFWULFLW\FRQVXPSWLRQ
At full load elmax
kW
0,04
At part load elmin
kW
0,02
In standby mode PSB
kW
0,004
6HDVRQDOVSDFHKHDWLQJHQHUJ\HႈFLHQF\Ș
s
%
93
6HDVRQDOVSDFHKHDWLQJHQHUJ\HႈFLHQF\FODVV
A
For boiler space heaters and boiler combination heaters:
8VHIXOHႈFLHQF\
$WUDWHGKHDWRXWSXWDQGKLJKWHPSHUDWXUHUHJLPHȘ
4
%
88,3
At 30 % of rated heat output and low-temperature regime
Ș
1
%
97,7
)RUFRJHQHUDWLRQVSDFHKHDWHUV8VHIXOHႈFLHQF\
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUGLVDEOHGȘ
Sup0
%
-