42
R2K 34 RAIN - RAD - ING - Man.Inst. - 1901.1_V3_firm.L224C_AHS
2 T
abella par
ametri_MIAH4_firm.L224C_EN
2. FIRST START-UP
SUPPOR
T
C
ENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P32
ENABLING FLOWMETER
(ONLY WITH FLOWMETER KIT CODE 65-00712 CONNECTED)
THROUGH THIS PARAMETER IT IS POSSIBLE TO ENABLE THE FLOWMETER
FOR MEASURING THE HEATING FLOW RATE AND MANAGE ACTIVATION OF
THE BOILER BY THE FLOW RATE ITSELF.
0 = DISABLED
(SET BY DEFAULT)
1 = ENABLED
P33
MINIMUM THRESHOLD TO ACTIVATE THE BOILER THROUGH THE FLOWMETER
(ONLY IF PARAMETER P32 IS SET ON THE VALUE ‘1’)
THROUGH THIS PARAMETER IT IS POSSIBLE TO SET THE MINIMUM WATER
FLOW RATE REQUIRED TO ACTIVATE THE BOILER.
20 - 68
VALUE EXPRESSED IN
HERTZ
20 Hz = 3.5 l/min
23 Hz = 4 l/min
28 Hz = 5 l/min
34 Hz = 6 l/min
39 Hz = 7 l/min
44 Hz = 8 l/min
50 Hz = 9 l/min
55 Hz = 10 l/min
61 Hz = 11 l/min
66 Hz = 12 l/min