USER INSTRUCTIONS

 

 

4

Starting - up the boiler 
 

  Open the gas Isolation valve located under the boiler. 

  Switch  on  the  boiler  by  placing  the  ON/OFF  switch 

(

1

)

 

in the 

ON

 position (see “Control panel”). 

  The  boiler  will  light  automatically  (with  the  WINTER 

mode selected and room thermostat connected). 

  Check  that  there  are  no  flashing  numbers  on  the 

display 

8

 (see error codes). If code 

H2O

 appears on 

the display 

8

 this denotes that there is no water in the 

boiler.  Consequently,  fill  the  system  as  described  in 
section “Filling the system”. 

 
 

 

■ 

“WINTER” mode 
 

To  switch  boiler  operation  to  “WINTER”  mode,  press 
button 

6

  (see  fig.  1).  The  boiler  will  only  work  for  the 

central heating system. The “WINTER” mode setting of the boiler is signalled by the symbol

 

lit continuously on 

the control panel. 

The automatic ignition system will light the burner every time there is a demand for room heating. In this case, the 

symbol

 

on the control panel will flash. 

 

 

■ 

Regulating the heating temperature 

 

The heating temperature is regulated by knob 

(see fig.1). 

  Rotating the knob anticlockwise reduces the temperature. 

  Rotating the knob clockwise increases the temperature. 

  The range of temperature settings for the central heating runs from a minimum of 30°C to a maximum of 80°C, 

or, in the case of low temperature operation, from a minimum of 25°C to a maximum of 59°C. 

 

Fig. 1

 

6

7

5

4

3

2

1

8

Summary of Contents for RAIN 30 E

Page 1: ...E 0694 RAIN 30 E R RAD ING MAN UT 1605 1 DIGITECH AUSTRALIA Technical specification RADIANT BRUCIATORI S p A Montelabbate PU User Manual for model RAIN 30 E R External wall mounted heating only boiler...

Page 2: ......

Page 3: ...ether the appliance has been tested by an authorised technician do not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL regis...

Page 4: ...APIDLY CLEAR THE ROOM CLOSE ALL GAS TAPS AND VALVES CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL Boiler controls Control panel LEGEND 1 ON OFF BUTTON 2 HEATING TEMPERATURE CONTROL KNOB 3 NOT OPERATIVE...

Page 5: ...mode press button 6 see fig 1 The boiler will only work for the central heating system The WINTER mode setting of the boiler is signalled by the symbol lit continuously on the control panel The autom...

Page 6: ...ons have been taken call an authorised Service Centre _E01_ Ionisation block Code E01 lit continuously on the display Check that the gas valve on the boiler and gas meter are open and that there is ga...

Page 7: ...Call the Service Centre N B If the boiler is to be left unused for a long period of time the user must do one of the following Make the boiler safe by disconnecting all the power supplies electricity...

Page 8: ...THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION...