USER INSTRUCTIONS

 

 

5

■  Topping-up the system with water 

 

The  water  pressure  in  the  central  heating  circuit  must  be 
checked during the entire period of operation of the boiler. 
In this respect, the reading on the pressure gauge 

M

 (fig. 

2), located on the lower part of the boiler, must not be less 
than 1 bar. 

If there is insufficient water in the boiler, the code 

H2O

 will 

flash on the display  (see fig 2).  

To  bring  the  system  back  up  to  pressure,  open  the 
external filling tap 

(fig. 2) and use the pressure gauge 

M

 

(fig.  2)  to  check  that  the  system  pressure  reaches  1  bar 
and that the code H2O lights up. 

When the operation is complete, close the fill tap.  

 

 

 
 
Diagnostics – Error codes: 
 

This paragraph contains a list of error codes that the boiler may generate on the display 

(see “Control panel”) 

together with the relative indications and the operations that the user can carry out to reset the boiler. 

 

If  the  problem  re-occurs  after  the  following  actions  have  been  taken,  call  an  authorised  Service 
Centre. 

 
 

_

E01

  

Ionisation block

 

Code 

E01 

lit continuously on the display.   

  Check that the gas valve on the boiler and gas meter are open and that there is gas in the mains supply (or in 

the tank).  

  Switch off then switch on the appliance using switch 

1

 (see “Control panel”) on the control panel. 

  When  the error code on the display disappears, the boiler will restart. 

If the problem persists, 

Call the Service Centre.

 

 

_

E02

_  

Safety Thermostat tripped

 

Code 

E02 

lit continuously on the display.  

Call the Service Centre.

 

 

_

h2o

_

  Water Pressure Switch tripped

 

Code 

H2O 

lit continuously on the display.   

  Check  the  water  pressure  in  the  central  heating  circuit.  The  reading  on  the  pressure  gauge 

M

  (see  fig.  2), 

located on the lower part of the boiler, must not be less than 1 bar . 

  If the pressure is less than 1 bar, top-up the system as described in paragraph “Filling the system”. 

  The boiler will restart automatically. 

If the problem persists, 

Call the Service Centre.

 

 

_

E05

 

Heating Sensor malfunction

 

Code 

E05 

lit continuously on the display.  

Call the Service Centre. 

 

_

E14

Air Pressure Switch malfunction

 

R

M

Fig. 2

 

Summary of Contents for RAIN 30 E

Page 1: ...E 0694 RAIN 30 E R RAD ING MAN UT 1605 1 DIGITECH AUSTRALIA Technical specification RADIANT BRUCIATORI S p A Montelabbate PU User Manual for model RAIN 30 E R External wall mounted heating only boiler...

Page 2: ......

Page 3: ...ether the appliance has been tested by an authorised technician do not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL regis...

Page 4: ...APIDLY CLEAR THE ROOM CLOSE ALL GAS TAPS AND VALVES CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL Boiler controls Control panel LEGEND 1 ON OFF BUTTON 2 HEATING TEMPERATURE CONTROL KNOB 3 NOT OPERATIVE...

Page 5: ...mode press button 6 see fig 1 The boiler will only work for the central heating system The WINTER mode setting of the boiler is signalled by the symbol lit continuously on the control panel The autom...

Page 6: ...ons have been taken call an authorised Service Centre _E01_ Ionisation block Code E01 lit continuously on the display Check that the gas valve on the boiler and gas meter are open and that there is ga...

Page 7: ...Call the Service Centre N B If the boiler is to be left unused for a long period of time the user must do one of the following Make the boiler safe by disconnecting all the power supplies electricity...

Page 8: ...THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION...

Reviews: