5.4 Converting the boiler to a different gas type
The conversion of a boiler from burning natural gas to LPG, or vice versa, must be carried out
exclusively by professionally qualified authorised personnel, registered in accordance with current
legislation and authorized by Radiant Bruciatori Spa.
Check that the gas supply pipe is suitable for the new fuel type.
Conversion is performed as follows:
•
Select the new gas type by changing parameter no.P02 (see ‘Parameters table’ 5.2);
•
Unscrew the aluminium plug and insert the analyser in the exhaust sampling point PF (see fig.1 paragraph 4.5)
to check the CO value. Make sure that the value complies with that reported in table 1 (paragraph 4.5);
•
If the CO2 value does not correspond to the specified value, adjust screw V (see fig. 1 paragraph 4.5) on the
venturi clockwise to reduce the CO2 value or anticlockwise to increase it;