background image

USER INSTRUCTIONS

 

 

 

3

Starting - up the boiler 

  Open the gas Isolation valve located under 

the boiler. 

  Switch on the boiler by placing the ON/OFF 

switch (

1

)

 

in the 

ON

 position (see “Control 

panel”). 

  The boiler will light automatically (with the 

WINTER mode selected and room thermostat 
connected). 

  Check that there are no flashing numbers on 

the display 

8

 (see error codes). If code 

H2O

 

appears on the display 

8

 this denotes that 

there is no water in the boiler. Consequently, 
fill the system as described in section “Filling 
the system”. 

 

 

“SUMMER” mode  

To switch boiler operation to “SUMMER” mode, press button 

6

 (see fig. 1). The boiler will only work for the D.H.W 

system. The “SUMMER” mode setting of the boiler is signalled by the symbol

 

lit continuously on the control 

panel.  

The automatic ignition system will light the burner every time there is a demand for domestic hot water. In this 

case, the symbol

 

on the control panel will flash.  

 

 

“WINTER” mode 

To switch boiler operation to “WINTER” mode, press button 

6

 (see fig. 1). The boiler will only work for the central 

heating system. The “WINTER” mode setting of the boiler is signalled by the symbol

 

lit continuously on the 

control panel. 

The automatic ignition system will light the burner every time there is a demand for room heating. In this case, the 

symbol

 

on the control panel will flash. 

 

 

“SUMMER-WINTER” mode  

To switch boiler operation to “SUMMER/WINTER” mode, press button 

6

 (see fig. 1). The boiler will work for both 

central heating/D.H.W systems. The “SUMMER/WINTER” mode setting of the boiler is signalled by the symbols 

 

 

lit continuously on the control panel. 

The automatic ignition system will light the burner every time there is a demand for room heating or domestic hot 

water, the functioning is signalled by the symbols 

 

flashing continuously on the control panel. 

 

 

Regulating the heating temperature 

The heating temperature is regulated by knob 

(see fig.1). 

  Rotating the knob anticlockwise reduces the temperature. 

  Rotating the knob clockwise increases the temperature. 

  The range of temperature settings for the central heating runs from a minimum of 30°C to a maximum of 80°C, 

or, in the case of low temperature operation, from a minimum of 25°C to a maximum of 59°C. 

 

6

7

5

4

3

2

1

8

Fig. 1

 

Summary of Contents for RKR 25

Page 1: ...CE 0694 RKR 25 RAD ING MAN UT 0906B DIGITECH 2 Technical specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH User Manual for model RKR 25 Premix condensing boiler...

Page 2: ......

Page 3: ...BY PROFESSIONALLY QUALIFIED PERSONNEL registered in accordance with current legislation Make sure that the requirements relating to the air intake and ventilation of the room in which the boiler is t...

Page 4: ...S CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL Boiler controls Control panel LEGEND 1 ON OFF SWITCH 2 HEATING TEMPERATURE CONTROL KNOB 3 D H W TEMPERATURE CONTROL KNOB 4 D H W TEMPERATURE DISPLAY BUTTO...

Page 5: ...will only work for the central heating system The WINTER mode setting of the boiler is signalled by the symbol lit continuously on the control panel The automatic ignition system will light the burne...

Page 6: ...may generate on the display 8 see Control panel together with the relative indications and the operations that the user can carry out to reset the boiler If the problem re occurs after the following...

Page 7: ...E22_ Parameter programming request Code E22 lit continuously on the display Call the Service Centre _E35_ Flame Detection Malfunction Code E35 lit continuously on the display Call the Service Centre N...

Page 8: ...THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION...

Reviews: