RB8762CJF Designer’s Guide (RRD2Z50‐20190314001‐A09‐C2)
20
AT-Command in Docklight
Master EVB
Slave EVB
Step 1.
Enter “
at+role=1<CR><LF>
” to set as master.
Step 5.
Enter “
at+inq<CR><LF>
”. Get slave’s BD
address.
OK. At+inq<CR><LF>
+INQ<CR><LF>
0:0X0012A1123456
Step 6.
Enter “
at+sinq<CR><LF>
”. Stop the master from
searching BT device.
+INQE<CR><LF>
Step 7.
Enter “
at+conn0<CR><LF>
”. Connect to slave
device.
OK<CR><LF>
+CONNS<CR><LF>
+CONNECTED>>0X12A1123456<CR><LF>
Step 2.
Enter “
at+role=0<CR><LF>
” to set as slave.
Step 3.
Enter “
at+name<CR><LF>
”
to read device
name.
+Name=Radicom
Step 4.
Enter “
at+laddr<CR><LF>
” to read BD address.
+LADDR=0012A1123456
※
Device will enter data mode as long as connect. If you want access command mode again,
please send “+++ath” to the connecting device. The device will leave data mode and enter
command mode.
※
Once power on the device, please wait 8 seconds to enter advertising mode.