background image

 

RW8300E-a-PR (USB) Designer’s Guide (RRD2Z50-20200130001) 

 

39 

4.1.5  After upgrade RW8300E / RW8300E-NL firmware. reset to default setting 

by reset button. Please check “WPS/RESET Button on RW8300E-a-PR 
(USB-Device)” on page 15. 
 

4.2 Check firmware version 

4.2.1  Open a browser and go to RW8300E / RW8300E-NL web page.  
4.2.2  Click “

Management

” on the left side and click “

Status

”. Current firmware 

version will be shown on “

Firmware Version

” line. In this example. 

firmware version is “

RW8300-NL-D.RRI.007_3.4.6.6

”. 

 

 

Status Page 

4.3 How to check md5sum of firmware 

This example operates on Fedora 20 system. 

4.3.1  Press “Windows Key” to go to search box. 

 

 

Windows key 

 

4.3.2  Key in “

gnome-terminal

” to open terminal application. 

 

 

Search gnome-terminal 

 

4.3.3  After getting new firmware (bin file) and release note from Radicom. please 

confirm if files are existed in correct directory by typing command “ls” in 
download directory. 

 

Check new firmware file 

Summary of Contents for RW8300E-a-PR

Page 1: ...Guide for the RW8300E a PR A set of paired devices RW8300E NL RW8300E RW8300E RW8300E NL Firmware version RW8300E NL RW8300E a NL RRI 041_3 4 6 6 RW8300E RW8300 D RRI 110_3 4 6 6 Compliant Date Jan 3...

Page 2: ...ocess of RW8300E a PR 17 Various Connection Processes of RW8300E a PR 18 Trouble Shooting 21 Reset RW8300E a PR USB Device to the Default 28 Upgrade RW8300E a PR firmware 29 Get RW8300E NL web page on...

Page 3: ...s The RW8300E a PR combines one RW8300E and one RW8300E NL into a single automatically paired wireless connection between a device based with USB host to a Wi Fi router with Ethernet This combination...

Page 4: ...lity Built in TCP IP stack Channel management and co existence Support Wake On WLAN via Magic Packet and Wake up frame Transmit Opportunity TXOP Short Inter Frame Spaces SIFS bursting for higher multi...

Page 5: ...7 V2 2 1 ETSI EN 300 328 V2 1 1 EN 62311 2008 Medical E E Certification IEC 60601 1 2005 A1 2012 EN 60601 1 2006 A1 2013 Medical CE EMC Certification EN 60601 1 2 2014 Ed4 0 EN 60601 1 2006 A1 2013 FC...

Page 6: ...ough WiFi and will get an IP address 192 168 137 100 as an USB NIC of connected device WISP Wireless Internet Service Provider NIC Network Interface Controller WARNING Please ensure the AP router is n...

Page 7: ...E NL RJ45 cable and power adapter CE PN 4000 0001 02 RW8300E a PR 3 ANZ PN 9500 0879 23 Include RW8300E RW8300E NL RJ45 cable and power adapter AU PN 4000 0001 03 RW8300E a PR 4 UK PN 9500 0879 24 Inc...

Page 8: ...Mexico Japan others Power Adapter for CE PN 4000 0001 02 Power adapter Europe CE connects to RW8300E 100 240VAC 5VDC 1A USB mini B Type Plug types Type C is used for Europe So America Asia others Powe...

Page 9: ...l RW8300E a PR Label Remover Yellow Package box PN 4100 0268 00 Box RW8300E a PR package box Package label PN 2400 0662 01 Label RW8300E a PR 1 package label PN 2400 0662 02 Label RW8300E a PR 2 packa...

Page 10: ...ting temperature 0 50 o C Humidity 95 RH IP classification protection against harmful ingress of water and particulate matter Ingress Protection Rating 21 RW8300E WiFi Ratings 25 C Parameter Min Typic...

Page 11: ...300E a PR USB Designer s Guide RRD2Z50 20200130001 11 Physical Description RW8300E NL Size Weight 2 7 x 1 4 x 1 0 67 4 x 35 8 x 26 4mm 36 1g RW8300E Size Weight 2 7 x 1 4 x 1 0 67 4 x 35 8 x 26 4mm 30...

Page 12: ...Guide RRD2Z50 20200130001 12 RW8300E a PR Standalone Product Mechanical Diagram Size RW8300E Size 67 4 x 35 8 x 26 4mm 2 65 x 1 41 x 1 04 RW8300E NL Size 67 4 x 35 8 x 26 4mm 2 65 x 1 41 x 1 04 Unit...

Page 13: ...Not used 5 Not used 6 RD Receive Data 7 Not Used 8 Not Used Ethernet Port Connector Pin Definitions Standard RJ45 10 100 BASE T Port A RJ45 connector is used for Ethernet twisted pair links The RJ45 c...

Page 14: ...NL 1 Glowing RW8300E a PR is power on and ready 2 Blinking in 2 seconds RW8300E a PR could connect to internet 3 Blinking in 1 2 seconds RW8300E a PR will reboot after release the reset button 4 Blin...

Page 15: ...RW8300E a PR USB Device 1 RESET multi functional button MFB MFB button supports reboot and reset functions Reboot RW8300E a PR Press MFB for 2 5 seconds Reset RW8300E a PR factory default setting Lon...

Page 16: ...RW8300E NL if your machine does not have pre install driver RW8300E NL also has the capability to automatically load the driver into your machine WARNING Please ensure the AP router is not 192 168 137...

Page 17: ...Connect RJ45 Ethernet cable from your computer to the Internet router to make your computer access to Internet via the RJ45 connection Ensure the router accepts RJ45 and test the connection 2 Once th...

Page 18: ...vironment 1 Windows XP Device 1 1 Plug RW8300E NL into USB port on your device 1 2 Once system detected USB device it will install USB driver automatically If it doesn t detect automatically follow th...

Page 19: ...f device doesn t play setup automatically please manually executed CD Driver AutoPlay Setup 2 3 Manually executed auto play to setup Wait for one minute You ll see green LED is flashing on both RW8300...

Page 20: ...th RW8300E NL Now you have Internet on the device again If it doesn t work please check trouble shooting on page 21 4 Linux Device 4 1 Plug RW8300E NL into USB port on your device It s not necessary t...

Page 21: ...e and renew IP address 1 1 Windows Device 1 1 1 Press Windows Key R to open search box Windows key 1 1 2 Key in cmd to open terminal application 1 1 3 Execute ipconfig release command to release all I...

Page 22: ...e plug RW8300E NL To check DNS status key in ping www radi com 2 3 If ping program connect times out setup DNS server in operation system 3 Setup DNS server in operation system 3 1 Windows Device 3 1...

Page 23: ...or does not exist you can ignore it and key in ipconfig all to check DNS server Response message Check DSN setting 3 1 5 If you see the message The requested operation requires elevation Run as admin...

Page 24: ...system If the RW8300E NL runs under others Linux distribution please ask IT members or contact Radicom 3 2 1 Set DNS through GUI 3 2 1 1Press Windows Key to enter search box Windows key 3 2 1 2Key in...

Page 25: ...Designer s Guide RRD2Z50 20200130001 25 3 2 1 4Click USB Ethernet on the left side and then click gear symbol to open configuration window Network setup window 3 2 1 5Click IPv4 on the left side Netwo...

Page 26: ...RW8300E a PR USB Designer s Guide RRD2Z50 20200130001 26 3 2 1 6Key 8 8 8 8 in textbox of DNS Then click plus symbol Key in 8 8 4 4 to second textbox and click Apply Before set DNS After set DNS...

Page 27: ...de RRD2Z50 20200130001 27 3 2 1 7Open terminal application and key in systemctl restart NetworkManager to restart network interface Restart network interface 3 2 1 8Key in cat etc resolv conf to check...

Page 28: ...power on RW8300E NL and wait one minute for startup 2 Insert a pin into the RESET hole long press RESET button over 5 seconds until LED flash within 1 8 seconds Then release RESET button and wait 2 mi...

Page 29: ...only for version RW8300 D RRI 110T_3 4 6 6 RW8300E a NL RRI 041T_3 4 6 6 1 Connect to web page of RW8300E and RW8300E NL 1 1 RW8300E 1 1 1 Follow below figure to set up environment of RW8300E to upgr...

Page 30: ...RW8300E a PR USB Designer s Guide RRD2Z50 20200130001 30 RW8300E web page...

Page 31: ...of RW8300E NL updating firmware 1 2 1 Power on RW8300E NL and wait 80 seconds 1 2 2 Turn on DHCP service of the USB NIC in the device will get an IP address 192 168 137 100 To know more details about...

Page 32: ...1 Press Windows Key to enter search box Windows key 2 1 2 Key cmd in search box and press Ctrl Shift enter to run terminal as administrator purview Open terminal as administrator purview Terminal of a...

Page 33: ...address and subnet Command format netsh interface ipv4 set address name Interface name static IP Address Subnet Mask Command sample 2 1 5 Key in ipconfig to check IP address Check IP address 2 2 Linux...

Page 34: ...ey in ifconfig to check the name of LAN interface Check name of LAN interface 2 2 4 Key in ifconfig enp0s25 192 168 1 100 to set IP address Command format ifconfig Interface name IP address Command sa...

Page 35: ...n IP address automatically DHCP 3 1 Windows Device 3 1 1 Press Windows Key to enter search box Windows key 3 1 2 Key cmd in search box and press Ctrl Shift enter to run terminal as administrator purvi...

Page 36: ...k name of LAN interface 3 1 4 Key in netsh interface ipv4 set address name Local Area Connection 6 source dhcp to set static IP address and subnet Command format netsh interface ipv4 set address name...

Page 37: ...5sum 4 1 Upgrade firmware 4 1 1 Open a browser and go to RW8300E RW8300E NL web page 4 1 2 Click Management on the left side and click Upgrade Firmware RW8300E RW8300E NL web page 4 1 3 Click Browse t...

Page 38: ...tus Current firmware version will be shown on Firmware Version line In this example firmware version is RW8300 NL D RRI 007_3 4 6 6 Status Page 4 3 How to check md5sum of firmware This example operate...

Page 39: ...10_3 4 6 6 bin to obtain md5sum number Command format as md5sum filename Create md5sum of new firmware 4 3 5 Key in cat ReleaseNote txt and find out the correspondent release version Then please compa...

Page 40: ...041T_3 4 6 6 Because RW8300E is a pure LAN to WiFi device there s no need to change its setting There are four ways to get the web page of RW8300E NL after assign the final IP address including brows...

Page 41: ...RW8300E a PR USB Designer s Guide RRD2Z50 20200130001 43 EMC Guidance and Manufacturer s Declaration Test Voltage kV ESD in air discharge 15KV ESD in contact discharge 8KV...

Page 42: ...uct with the modules installed needs to be tested for FCC Part 15 IC Industry Canada CE EMI RF compliance Radicom certification documentation will help streamline the final product approval process Co...

Page 43: ...s 2377A RW8300M Radio Frequency RF Exposure Information D claration d exposition aux radiations Cet quipement doit tre install et utilis conform ment aux instructions fournies et les antennes utilis e...

Page 44: ...at interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and...

Page 45: ...2 2014 EN 61000 3 3 2013 ETSI EN 301 489 1 V1 9 2 EN 301 489 17 V2 2 1 ETSI EN 300 328 V2 1 1 EN 62311 2008 This equipment is marked with the and can be used throughout the European community France 2...

Page 46: ...s no obligation or liability for additions or modifications to this warranty In no case does RRI warrant the installation maintenance or service of the Product RRI is not responsible in any way for an...

Page 47: ...placement or refund of the purchase price at RRI s option is the exclusive remedy THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER EXPRESSED WARRANTIES ANY APPLICABLE IMPLIED WARRANTIES INCLUDING WITHOUT L...

Page 48: ...s Guide RRD2Z50 20200130001 51 Contacting Radicom Research If more information or technical support is needed please contact us 671 E Brokaw Road San Jose CA 95112 USA Telephone 408 383 9006 Fax 408 3...

Reviews: