36000 Kraljevo, Živojina Lazića
- Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150, http://www.radijator.rs
e-mail: radijator@radijator.rs
97
-
During the process of maintaining the flames the fanfor primary combustion is switched
on with the power which determined by the parameter Uc09.
Possible mistakes in the work related to the maintenance phase of the flame:
Boiler operation, beside the functioning of the phase of flame maintenance, does not have
enough pellets for the start and work in normal mode.
Eliminating the cause of mistake:
1. Reduce the parameter t04, i.e. increase the frequency of conveyor and fan work in the
phase of idle work.
2. Increase the duration of the process time, ie. The parameter t05.
Too much of unburnt pellet when boiler starting its work.
Eliminating the cause of mistake:
1. Increase the parameter t04
2. Reduce the parameter t05
3. Reduce the fan power for the primary combustion in the maintenance phase
–
the
parameter Uc09.