combustion chamber and a reduction in the flame and the boiler is extinguished.
(Extinguishing).
➢
The process of resolving the
Problem 1
. Increase the fan power. It is best to increase the
fan power in all modes through the function of calibration (Calibration-exhaust fan).
Possible
cause 3.
➢
Problem 2.
Boiler
BIO
lux
UNI 20
works, but in the course of work there comes to a
stoppage and a sign is displayed-Modulation, and then to the Safety shutdown
(Extinguishing). At the end the display indicates the error Er05.
➢
The process of resolving the
Problem 3
. This occurs because the flue gas temperature is
too high. The most common causes are contamination of the boiler, the chimney is too
strong, too strong fans in operating mode, excessive loading of pellets, pellet
characteristics, and so on. The delay can be eliminated by adjusting some of the
parameters or by increasing parameters for passing the boilers into modulation and safety
shutdown, due to flue gases, which are parameters Th07, Th08.