49
Radijator Inženjering d.o.o, 36000 Kraljevo, Živojina Lazića - Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150, http://www.radijator.rs
e-mail: radijator@radijator.rs
For cold water, install at least one additional safety pressure valve.
The air vent belongs to the same safety group as the safety pressure valve.
Air flow sensor (Picture 5):
regulates the fuel combustion while the device is running.
Picture 5. Air flow sensor
The flue gas pressure switch (Picture 6):
measures the pressure of gases in the furnace in
case you didn’t close well any of the lids (while cleaning, etc.) or didn’t close the door well
and, in that case, the device initiates stove shutdown sequence and displays an error. That is
the additional stove safety protocol.
Picture 6. Flue gas pressure switch
These conditions may lead to a worse discharge of the combustion products,
especially carbon monoxide which can, in extreme cases, impair health and even lead
to suffocation.
The safety thermostat of the water pellet stove
(
Picture 7
):
Picture 7. Safety thermostat
The safety thermostat has safety functions as a water temperature limiter in the boiler. This
thermostat is so-called operational and serves to limit temperature to the user-wanted level.