8.4. Start-up and working errors of the CUBA pellet stove.
All possible errors in the initial working stage, more precisely during firing, even during its
operation are reported on the display by the automatic controls. (
Picture 17
- error signaling
ALARM).
Error tags and clarifications are given in the following table.
Er01
Error –
High voltage 1. The safety thermostat is activated.
Er02
Error -
High voltage 2. The safety air pressure switch is activated.
Er03
Error –
Shutting down when the temperature of smoke channel gases is below
anticipated.
Er04
Error -
Shutting down when the temperature of water is above the set value.
Er05
Error -
Shutting down when the temperature of the smoke channel gases exceeds
the anticipated value.
Er07
Error -
Encoder. This error occurs due to the shortage of the encoder signal.
Er08
Error -
Encoder. This error is related to the bad encoder loading
Er09
Error –
Low water pressure
Er10
Error
– High water pressure
Er11
Error –
Real time , sistemska greška
Er12
Error –
Shutting down due to the failed ignition
Er15
Error –
Lack of voltage
Er17
Error –
on the regulator of the airflow sensor
Er18
Error –
Shortage of pellets
Er39
Error -
Malfunctioning regulator of the airflow sensor
Er41
Error –
The minimum airflow isn’t achieved
Er42
Error –
The maximum airflow is above anticipated.
All possible operating problems and failures of this device can be divided into two large
groups.
Group I.
The operating failure during the first ignition, more precisely during the
very first ignition upon purchasing the boiler or the first initiation during a day.
Group II.
The failure which occurs if the boiler worked already and the display had a
notification (Run Mode), but after reaching the set temperature and being in standby
mode loses the combustion continuity.
Group I
The most frequent signalization on the display, related to this group of errors, is
Er12
.
During the first ignition upon installing the boiler to the hydro installation, instructions from
the ‘starting the pellet stove’ section should be followed.