During maintenance and servicing of the boiler, disconnect the boiler from
the power supply.
If condensation appears in the boiler during usage, it is necessary to collect the condensed matter
and the entire inside of the boiler should be coated with basic means for cleaning or, at least,
with aqueous solution of construction lime. In this way the neutralization of acids is carried out
due to condensation.
In this way, make sure to preserve the boiler at the end of the heating season. In that
situation, also close all the openings on the boiler to prevent air circulation through the boiler
to avoid potential appearance of moisture in the boiler.
Maintenance of the boiler is one of the most important factors affecting the boiler life
expectancy. It is particularly important to clean the boiler when it is not the heating season
and neutralize the acid, as described above.
8. Name plate
Name plate is stuck on a visible place on the boiler and contains the following data (see the picture in the
item STICKERS)
1.Technical data on the sticker:
Manufacturer (Radijator Inženjering)
Serial number of the boiler (example: N°:100113033)
Year of production (example: 2019)
Type of the boiler (Ecoflame Plus 25 or Ecoflame Plus 30)
Nominal power of boiler
Heat output range
Necessary chimney draft (18Pa)
Electric voltage (230V)
Frequency (50Hz)
Current (3A)
Nominal electrical power (490W)
Maximum extended electrical power (200W)
All el. power (690W)
Weight
Boiler class as per EN3035 (5)
Maximum pressure (3 bar)
Maximum temperature (90°C)
Quantity of water in litres