Radijator Inženjering d.o.o, 36000 Kraljevo, Živojina Lazića - Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150, http://www.radijator.rs
e-mail: radijator@radijator.rs
80
Ignition Block
Message that appears if you try to turn off the system in the ignition phase. The
system will turn off only after it has entered the Run mode.
Er06
Thermostat Pellet open.
Er20
In the basic configuration, appearance of this error has not been envisaged. In case it
appears, call the certified service technician.
7.1.4 Monitoring
In order to access the screen for monitoring, press the button P4 ili P6:
Exhaust T.
Exhaust temperature [°C]
Boiler T.
Boiler temperature [°C]
Boiler Return T.*
Boiler return temperature [°C]
Buffer T
Buffer temperature [°C]
DHW T.
Domestic hot water temperature [°C]
Fan Speed
Combustion Fan speed [rpm]
Auger
Auger work time [s]
Product Code 549
Product Code
*This value is not available in the standard scope of delivery.
User Menu 1
In order to access this menu, press button P3.
Combustion
Management
Pellet power
This Menu allows to set the system’s combustion in automatic or manual mode. If the
manual mode is set, the user must also choose the combustion power.
Auger Calibration
Menu to change the Auger’s work time or speed. The system has 10 calibration steps (0
value is set by the factory). The calibration effect is valid only in Run Mode and
Modulation. For each step the value is increased in percentage for the value P15.
Example:
P15
=10%, Step= -1
Default
values
C03=2,0
C04=3,0
C05=4,0
C06=5,0
C07=6,0
C11=1,0
Calibrated
values
C03=1,8
C04=2,7
C05=3,6
C06=4,5
C07=5,4
C11=0,9