background image

 

 

W

IRELESS 

V

OLTAGE 

S

ENSOR

 

 

 

C

OPYRIGHT 

©

 

2019,

 

R

ADIO 

B

RIDGE 

I

NC

.

          

 W

IRELESS 

V

OLTAGE 

S

ENSOR

 

P

AGE 

5

 OF 

13

 

 

5.

 

T

EST 

M

ESSAGES

 

 

The sensor can be triggered to send test messages by placing a magnet next to the side of the 
sensor. The location of the magnet is indicated by the triangular notch on the side of RBSx01 
and RBSx05 sensors. RBSx04 sensors do not have this capability. There is a small magnetic Hall 
effect sensor that will detect the presence of a magnet and send a message. This can be used for 
diagnostic purposes to ensure the sensor is within range and connected to the network. 

 

6.

 

M

ESSAGE 

P

ROTOCOL

 

 

This section defines the protocol and message definitions for the sensor.  

 

If the standard Radio Bridge console (console.radiobridge.com) is not used, refer to this section 
to decode the sensor data and configure the sensor through downlink messages. 

Radio Bridge provides a web-based console at console.radiobridge.com 
to configure and monitor sensors. Usage of this console is highly 
recommended for most customers rather than implementing the 
protocols defined in this section. 

 

 

 

6.1.

 

Common Messages 

 

There are common messages across all wireless sensors that are defined in the document 

“Common Sensor Messages” which is available on the Radio Bridge website. 

 

 

Common messages include basic error messages, tamper, supervisory, and downlink ack. It is 
important to refer to that document prior to decoding the messages defined in this section. 

Refer to the document “Common Sensor Messages” for definitions of all 

common messages. Common messages are not defined in this document.

 

 

 

 

Summary of Contents for RBS306-VM30-EU

Page 1: ...Wireless Voltage Sensor User Guide VERSION 1 1 SEPTEMBER 2019...

Page 2: ...SSAGE PROTOCOL 5 6 1 Common Messages 5 6 2 Uplink Messages 6 6 3 Downlink Messages 7 6 3 1 Threshold Mode 7 6 3 2 Report on Change Mode 8 6 3 3 Periodic Reports 9 7 MECHANICAL DRAWINGS 10 7 1 INDOOR R...

Page 3: ...ADC to measure an analog value between 0 30V and provides 10mV of resolution If the measured value rises above or falls below the configured thresholds an alert is sent over the wireless network Feat...

Page 4: ...Conventions Table 2 Document Conventions Font Icon Meaning Important notes Warnings and cautions 2 4 Part Numbers Table 3 Part Numbers Part Number Rating Wireless Region RBS306 VM30 US Outdoor Industr...

Page 5: ...age for the life of the battery and then experience a rapid drop near the end whereas an alkaline battery will experience a more gradual reduction in voltage over time Radio Bridge sensors are shipped...

Page 6: ...ard Radio Bridge console console radiobridge com is not used refer to this section to decode the sensor data and configure the sensor through downlink messages Radio Bridge provides a web based consol...

Page 7: ...nt Event Payload see Voltage Measurement Event Payload Definitions 1 2 Voltage measurement in units of 10mV range 0 3000 The voltage measurement event is defined in the following table Table 6 Voltage...

Page 8: ...rts The remainder of the payload bytes 1 6 are determined by the mode selected and defined in the next two sections 6 3 1 Threshold Mode Threshold mode is set when byte 0 of the payload is set to 0x00...

Page 9: ...set to 0 it is disabled Periodic reporting is described in the section Periodic Reports 6 3 2 Report on Change Mode Report on Change mode is set when byte 0 of the payload is set to 0x01 The remainde...

Page 10: ...n 1 minute increments when the most significant bit is 1 as shown in the following table Table 10 Period Bye byte 1 from Downlink Configuration Message Bit 7 Bits 6 0 0 Period defined in hours 1 127 h...

Page 11: ...RADIO BRIDGE INC WIRELESS VOLTAGE SENSOR PAGE 10 OF 13 7 MECHANICAL DRAWINGS The mechanical drawings provided in this section are for the main body of the sensor All dimensions are inches unless othe...

Page 12: ...WIRELESS VOLTAGE SENSOR COPYRIGHT 2019 RADIO BRIDGE INC WIRELESS VOLTAGE SENSOR PAGE 11 OF 13 7 2 ARMORED OUTDOOR INDUSTRIAL RBSX06 SENSORS...

Page 13: ...ID 2APNUSFM10R2 LoRaWAN RBS301 RBS304 and RBS305 sensors FCC ID 2APNUCMABZ LoRaWAN RBS306 sensors This device contains FCC IAU792U13A16858 This device contains equipment certified under IC 125A 0055...

Page 14: ...provides this document as is without warranty of any kind expressed or implied including but not limited to the implied warranties of fitness or merchantability for a particular purpose Radio Bridge m...

Reviews: