Uplink Messages 

The uplink message (sensor to web application) specific to the sensor is defined in following 
table. The common uplink messages are not included in this section (see common messages 
document). 

 

Table 5 Uplink Message 0x14: Voltage Measurement Event 

Byte 

Description 

Voltage Measurement Event Payload (see Voltage 
Measurement Event Payload Definitions) 

1-2 

Voltage measurement in units of 10mV (range 0-3000) 

 

The voltage measurement event is defined in the following table. 

 

Table 6 Voltage Measurement Event Payload Definitions 

Event Payload  Description 

0x00 

Periodic report 

0x01 

Analog measurement has risen above upper threshold 

0x02 

Analog measurement has fallen below lower threshold 

0x03 

Report on change increase 

0x04 

Report on change decrease 

 

The  voltage  measurement  field  in  the  uplink  message  is  the  analog  measurement  in 
increments of 10mV with a range of 0-30V (0-3000).  

 

 

 

Summary of Contents for RBS306-VM30-EU

Page 1: ...Wireless Voltage Sensor User Guide VERSION 1 1 SEPTEMBER 2019...

Page 2: ...SSAGE PROTOCOL 5 6 1 Common Messages 5 6 2 Uplink Messages 6 6 3 Downlink Messages 7 6 3 1 Threshold Mode 7 6 3 2 Report on Change Mode 8 6 3 3 Periodic Reports 9 7 MECHANICAL DRAWINGS 10 7 1 INDOOR R...

Page 3: ...ADC to measure an analog value between 0 30V and provides 10mV of resolution If the measured value rises above or falls below the configured thresholds an alert is sent over the wireless network Feat...

Page 4: ...Conventions Table 2 Document Conventions Font Icon Meaning Important notes Warnings and cautions 2 4 Part Numbers Table 3 Part Numbers Part Number Rating Wireless Region RBS306 VM30 US Outdoor Industr...

Page 5: ...age for the life of the battery and then experience a rapid drop near the end whereas an alkaline battery will experience a more gradual reduction in voltage over time Radio Bridge sensors are shipped...

Page 6: ...ard Radio Bridge console console radiobridge com is not used refer to this section to decode the sensor data and configure the sensor through downlink messages Radio Bridge provides a web based consol...

Page 7: ...nt Event Payload see Voltage Measurement Event Payload Definitions 1 2 Voltage measurement in units of 10mV range 0 3000 The voltage measurement event is defined in the following table Table 6 Voltage...

Page 8: ...rts The remainder of the payload bytes 1 6 are determined by the mode selected and defined in the next two sections 6 3 1 Threshold Mode Threshold mode is set when byte 0 of the payload is set to 0x00...

Page 9: ...set to 0 it is disabled Periodic reporting is described in the section Periodic Reports 6 3 2 Report on Change Mode Report on Change mode is set when byte 0 of the payload is set to 0x01 The remainde...

Page 10: ...n 1 minute increments when the most significant bit is 1 as shown in the following table Table 10 Period Bye byte 1 from Downlink Configuration Message Bit 7 Bits 6 0 0 Period defined in hours 1 127 h...

Page 11: ...RADIO BRIDGE INC WIRELESS VOLTAGE SENSOR PAGE 10 OF 13 7 MECHANICAL DRAWINGS The mechanical drawings provided in this section are for the main body of the sensor All dimensions are inches unless othe...

Page 12: ...WIRELESS VOLTAGE SENSOR COPYRIGHT 2019 RADIO BRIDGE INC WIRELESS VOLTAGE SENSOR PAGE 11 OF 13 7 2 ARMORED OUTDOOR INDUSTRIAL RBSX06 SENSORS...

Page 13: ...ID 2APNUSFM10R2 LoRaWAN RBS301 RBS304 and RBS305 sensors FCC ID 2APNUCMABZ LoRaWAN RBS306 sensors This device contains FCC IAU792U13A16858 This device contains equipment certified under IC 125A 0055...

Page 14: ...provides this document as is without warranty of any kind expressed or implied including but not limited to the implied warranties of fitness or merchantability for a particular purpose Radio Bridge m...

Reviews: