6100-Gfast Multifunction Copper Tester Operation Manual
© 2020 Radiodetection Ltd
129
Load Coil
13.2 xTalk TDR
The
xTalk TDR
test transmits on one pair and receives
on pair two allowing you to detect and isolate split pairs
which may be causing service disruptions. The test
adds a hookup diagram in the form of a
Confirmation
window at start up, showing you how to connect your
cables for this test.
When FED is
Enabled
on the
FED Setup
page, both
the T-R/A-B and T1-R1/A1-B1 pairs will be terminated
at the FED. The hookup diagram uses graphic and
textual components.
Proceed
button closes the hookup diagram
prompt and starts the test.
Cancel
button closes the hookup diagram
prompt only.
The
Continuous
function displays the line trace and is
continuously on and ready to use. It displays and
updates results in real time, in either
Portrait
or
Landscape Mode
, until you stop the test. The last valid
results then remain displayed.
Current Group
displays the test being
measured.
Current Test
allows you to select either
Auto,
Manual,
or
xTalk TDR
.
Note: The test has the same parameters as the
Manual
TDR
test and does not inherit
Auto TDR
settings
(
Range, Gain, Pulse Width
) when switching to
the test from the
Current Test
setup line.
Range
allows you to set the range from the
given list.
Gain
allows you select the gain test parameter
from the given list.
Pulse Width
allows you to select a value from
a given list.
Dual Trace Offset %
is a configurable offset
parameter for the secondary trace, with a
range of -100 % to +100 %.
Note: If the loaded secondary trace offset = 0, then the
primary and secondary traces will overlap.
VOP
allows you to change the velocity of
propagation value for the cable.
Current Trace
allows you to turn on/off
Live
and
Peak
traces by selecting one of the
following:
o
Live
turns
Peak Hold OFF
clearing
previously collected
minimum/maximum measurement
values. This is the default.
o
Live and Peak
turns
Peak Hold ON
and collects minimum/maximum
measurement values, displaying all 3
traces.