6100-Gfast Multifunction Copper Tester Operation Manual
© 2020 Radiodetection Ltd
167
IPTV Channel Analysis
-
Enable
to add
channels for analysis. If disabled, channel
analysis in auto test is not performed.
o
Stream Time
defines the length of
time, from 1 to 60 s, to keep the
channel stream(s) for analysis.
o
Channel 1-5
allows you to define up to
5 IPTV channels for concurrent
analysis.
On-screen function buttons:
o
Add/Insert
is available only when a
blank entry is highlighted. When the
button is pressed, the first available
channel from the alias
Channel List
is
automatically added to this list of
channels. Upon highlighting another
blank entry, the next channel from the
alias table is added, and so on.
o
Delete
removes the selected channel
from the list.
You can
Enable
either one or both, but you
cannot
Disable
both of them at same time. If
both tests are enabled,
Join/leave Test
runs
first.
To configure test setup values:
1. Press the up/down arrow keys to select the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen
and use the navigation keys to scroll through.
4. Press
to confirm the value.
Ping Test Setup
The
Test Setup
tab is available only if
Access Mode
is
not
Sync Only
.
Address Format
is
URL
,
IP Address
, or
Gateway
. When
IPv6 (DHCP)
is set as the
Access Mode
in
Connection Setup
,
IP
Address
is changed to
IPv6 Address
.
URL
/
IP Address
lists either the URL or IP
Address where the unit pings.
IPv6 Address
parameter replaces the
URL/IP
Address
when
IPv6 (DHCP)
is set as the
Access Mode
.
Packet Size
is a value from 32 through 1200 of
the number of bytes sent in one packet. The
default value is 32.
Total Pings
is the total number of Ping packets
to send out from 1 through 99. The default
value is 3.
Timeout
is the time in seconds from 1 through
10, that the unit will wait for a response back
from the destination device.
To configure test setup values:
1. Press the up/down arrow keys to select the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen
and use the navigation keys to scroll through.
4. Press
to confirm the value.