 WARNING! Direct connection to live conductors is POTENTIALLY LETHAL. 

Direct connections to live conductors should be attempted by fully qualified 
personnel only using the relevant products that allow connections to energized 
lines.

 WARNING! The transmitter is capable of outputting potentially lethal voltages. 

Take care when applying signals to any pipe or cable and be sure to notify other 
technicians who may be working on the line.

 WARNING! Reduce audio level before using headphones to avoid damaging 

your hearing.

 WARNING! This equipment is NOT approved for use in areas where 

hazardous gases may be present.

 WARNING! When using the transmitter, switch off the unit and disconnect 

cables before removing the battery pack.

 WARNING! The RD7200 locator will detect most buried conductors but there 

are some objects that do not radiate any detectable signal. The RD7200, or any 
other electromagnetic locator, cannot detect these objects so proceed with 
caution. There are also some live cables which the RD7200 will not be able to 
detect in Power mode. The RD7200 does not indicate whether a signal is from a 
single cable or from several in close proximity.

 WARNING! Batteries can get hot after prolonged use at full output power. 

Take care while replacing or handling batteries.

 WARNING! Only use charging equipment provided by Radiodetection. The use of 

alternative chargers may cause a safety hazard and/or reduce the life of the battery.

CAUTION: Do not let your battery completely discharge as this may reduce its life 
or damage it permanently. If you are not using your equipment for a long period 
do charge them at least once a month. 

 WARNING! Batteries can get hot after prolonged use at full output power. 

Take care while replacing or handling batteries.

 WARNING! Do not tamper with, or attempt to disassemble the battery packs.

CAUTION: If battery failure is suspected or if the battery shows any sign of 
discoloration / physical damage return the entire unit to an authorized repair 
center for investigation and repair. Local, national or IATA transport regulations 
may restrict the shipment of faulty batteries. Check with your courier for 
restrictions and best practice guidelines. Your local Radiodetection representative 
will be able to direct you to our authorized repair centers.

NOTE: The charging temperature range is 0 to 45 °C, 32 to 113°F. Do not attempt 
to recharge your batteries outside this temperature range.

3 Year Extended Warranty 

RD7200 locators and transmitters are covered by a 1 year warranty as standard. 
Customers can extend their warranty period to a total of 3 years by registering 
their products within 3 months of purchase. 

To register your product:

Visit 

https://portal.radiodetection.com

 to create your portal account* and use 

the Product page to register your locator or transmitter.
Visit 

https://support.radiodetection.com

 for instructions on how to create a 

portal account or register your product.

* A valid email address and mobile number are required.

eCert and Self-Test

The RD7200 locator is safety equipment which should be regularly checked to 
ensure its correct operation.
eCert provides a thorough test of the RD7200’s locating circuitry, and supplies a 
Radiodetection Calibration Certificate when a positive test result is obtained.
To run an eCert, the locator should be connected to an internet-enabled PC on 
which the RD Manager software is installed.
Refer to the RD Manager operation manual for further details. Additional purchase 
may be required.
RD7200 locators incorporate an Enhanced Self-Test feature. In addition to the  
typical checks for display and power functions, the RD7200 locator applies test 
signals to its locating circuitry during a Self-Test to check accuracy and performance.
We recommend that a self-test is run at least weekly, or before each use. 

Summary of Contents for RD7200

Page 1: ...RD7200 Utility cable and pipe locator range User Guide Guía del usuario Guide d utilisation Návod k použití 用户指南 Gebruikershandleiding 90 RD7200 UG INT 01 املستخدم دليل ...

Page 2: ...d as a quick reference guide only For detailed instructions including the use of accessories help with eCert please refer to the RD7200 locator Operation Manual and RD Manager Online manuals which are available for download from www radiodetection com The online User Manual library also contains links to the RD Manager Online manuals Certificates of conformity for the RD7200 locators and Tx transm...

Page 3: ...to disassemble the battery packs CAUTION If battery failure is suspected or if the battery shows any sign of discoloration physical damage return the entire unit to an authorized repair center for investigation and repair Local national or IATA transport regulations may restrict the shipment of faulty batteries Check with your courier for restrictions and best practice guidelines Your local Radiod...

Page 4: ...ocator screen icons 16 Signal strength bargraph with peak marker 17 Signal strength readout 18 Null Proportional Guidance arrows 19 Battery level 20 Sensitivity readout 21 Volume level 22 Radio Mode icon 23 Power Mode icon 24 Accessory Measurement icon 25 A Frame icon 26 Frequency current menu readout 27 Antenna modes icon Indicates antenna mode selection Peak Peak Null Guidance 28 Sonde icon Indi...

Page 5: ...ows 9 Measure key Transmitter screen icons 10 Battery level indicator 11 Operation mode readout 12 Standby icon 13 Output level indicator 14 Clamp icon Indicates when a signal clamp or other accessory is connected 15 DC Power connected indicator 16 Induction mode indicator 17 A Frame Indicates when the transmitter is in Fault Find Mode 18 Voltage warning indicator Indicates that the transmitter is...

Page 6: ...re available for both locators and transmitters providing superior performance over traditional alkaline batteries To fit these rechargeable packs follow the instructions provided with each pack System setup It is important that you set up the system according to regional operational requirements and your personal preferences before you conduct your first survey You can set the system up using the...

Page 7: ...t High or Low sound levels SWING Enable or disable Swing warning INFO Shows the software version run a Self Test display the date of the most recent service recalibration M CAL or the most recent eCert calibration Transmitter menu options VOL Adjust the speaker volume from 0 mute to 3 loudest FREQ Enable or disable individual frequencies BOOST Boost transmitter output for a specified period of tim...

Page 8: ... is better to use a low frequency on larger low impedance utilities and move to a higher frequency on smaller high impedance utilities The lowest power setting required to trace the target utility should always be used to minimize the risk of false trails The transmitter can apply a signal using three different methods Direct connection In direct connection you connect the transmitter directly to ...

Page 9: ...able or pipe being located or when the locator determines that signal conditions are too poor for reliable measurements Using accessories The locator and transmitter are compatible with a wide range of accessories For detailed information on using any of the accessories below please refer to the RD7200 locator operation manual Transmitter signal clamps When it is not possible to connect directly o...

Page 10: ...nals and connection sockets are clean free of debris and corrosion and are undamaged Do not use this equipment when damaged or faulty Batteries and power supply Only use the rechargeable battery packs chargers and power supplies approved by Radiodetection If not using rechargeable packs use good quality Alkaline or NiMH batteries only Batteries should be disposed of in accordance with your company...

Page 11: ...he or arrows 5 Press the key to select YES 6 Press the key to begin the Self Test 7 Once the Self Test is completed the result PASS or FAIL will be displayed 8 Restart the locator using the key RD Manager Online PC Software RD Manager Online is the RD7200 locator system PC companion and it allows you to manage and customize your locator RD Manager Online is also used to retrieve and analyze survey...

Page 12: ...n Germany Groendahlscher Weg 118 46446 Emmerich am Rhein Germany Tel 49 0 28 51 92 37 20 rd sales de spx com Radiodetection Asia Pacific Room 708 CC Wu Building 302 308 Hennessy Road Wan Chai Hong Kong SAR China Tel 852 2110 8160 rd sales asiapacific spx com Radiodetection China 13 Fuqianyi Street Minghao Building D304 Tianzhu Town Shunyi District Beijing 101312 China Tel 86 0 10 8146 3372 rd serv...

Reviews: