26
Special note for conditions: The helicopter and glider programming offers you the choice of COND. This
option allows you to have a separate rate for each of the 3 controls automatically selected when changing
conditions, for a total of FIVE rates available. Simply change the switch choice to COND. and then:
(HELI) press the CURSOR LEVER to toggle through the 5 conditions while setting the rates.
(GLID) activate the corresponding condition to edit the rates.
Goals
Steps
Inputs
Set up dual rates
and exponential
in HELI model.
Open D/R,EXP
for 1s.(If ADVANCE
again)
to D/R EXP,PUSH.
Choose channel
to CH, Push.
to desired channel. PUSH
Choose first channel position
to NO,PUSH.
to UP,PUSH.
Set rate and EXP(Ex: High
rate=95%,0%exponential)
to Rate, PUSH.
to 95%,confirm 0% EXP.
Go to 2nd switch position
and
set
rate
and
exponential.
to NO,PUSH
to DOWN,PUSH.
Optional: if using a 3 position
switch, set 3rd rate.
to NO,PUSH.
to COND repeat above.
Optional: assign dual rates
to have one for each
condition.
to SW,PUSH.
to COND.
Repeat steps above to adjust for each condition.
Goals
Steps
Inputs
Set up aileron triple rates on
SWITCH C with travel
settings of 75%(normal)
25%(slow roll)and 140%
(extreme aerobatics)and
exponential setting of
0%, +15%, and -40%
respectively.
NOTE: This normal rate has
no exponential so it has a
Very linear, normal feel.
This is slow roll rate has
positive exponential
(the opposite of what most
people normally uses),
which makes the servos
more responsive around
center. This makes the
servos feel the same around
center in the normal and low
rates, but still gives a very
slow roll rate at full stick.
3D
rate
(extreme
aerobatics)
has a very high distance of
travel nearly twice that of
the normally rate.
Therefore, using a very high
rate negative exponential
setting softens how the
servos responses around
center stick.
Open D/R,EXP
for 1s to BASIC
(
to
D/R,EXP,PUSH.
Choose channel to change
(Ex:aileron is already selected)
to CH,PUSH
,
to AILE,PUSH
Optional: Change switch position.
to SW,PUSH
to SWC,PUSH
Confirm switch is in desired
position and set rate.(Ex: up=high
rate,75%)
to D/R
C to UP position.
AILERON STICK
to75%.PUSH
AILERON STICK
to75%.PUSH
Move Switch to 2nd rate position
and set this particular rate (Ex:
center=low rate,25%)
SWC to center position,
to D/R
AILERON STICK
to25%
,
PUSH
AILERON STICK
to 25%
,
PUSH
Optional: If using a 3 position
SW, move SW to 3rd position
and set this rate.(Ex: DOWN=3D
rate, 140%)
SWC to DOWN position.
AILERON STICK
to140%
,
PUSH
AILERON STICK
to140%
,
PUSH