RadioLink Electronic Ltd
www.radiolink.com
17
4.5 Internal resistance
The battery internal resistance data can be viewed when charging.
Method: 10 seconds after charging starts, short press SET button to view all the internal resistance of
the battery being charged. Press SET again to return to the charging page.
4.6 Parameter viewing
When the charging stops, press "+/▲" or "-/▼" buttons at the bottom of the screen when it is on the
home page to select the battery port that needs to be viewed, and then press SET button to confirm
the selection to view the data of each cell of the battery. If you need to view the battery data of other
ports, press "+/▲" or "-/▼" buttons at the bottom of the screen to switch ports for data viewing.
Total voltage data of all batteries
Parameters of each cell of 4
th
port
Part 5. Firmware Upgrade
5.1 Firmware selection
1. Black-and-white screen CB86: The latest firmware is not suitable for CB86 with a black-and-white
screen. Improper upgradation will cause a white screen when the charger is powered on. And the
charger needs to install the old version firmware again and re-calibration.
2.
Color screen CB86-PLUS: Connect the charger to the computer via USB cable.
If the charger
screen stays on
, you can only install firmware of Bin file. Computers with XP, win7-win10 system are
supported for firmware upgrade. (Note: If computer with win 10 system is selected to upgrade the