and flash. The flashing time (the interval between two flashes) of the lights flashing will vary according to the 

different prompts of the system.

 

 

COOL 9030 ESC indicates the status of the system not only by the two indicator lights, but also by the vibration 

and  sound  principle  of  the  motor.  The  combination  of  the  two  ways  achieves  the  sound  and  light  prompt 

function of the ESC system. There are three sound prompt states of the motor, including short beep, long beep, 

and tone beep state. The number of beeps and beep intervals in the three prompt states will vary according to 

different prompts of the system.

 

 

At the same time, the sound of the motor and the indicator light of this ESC system can work independently or 

coordinately.  There  is  only  motor  sound  prompt  or  only  light  prompt  when  in  some  status  of  the  system 

(independently), while there are both motor sound prompt and indicator light prompt when in some other status 

of the system (coordinately).

 

 

5.1 Motor sound 

When the device is started normally, the red and green indicators light should be always on, and the motor will 

make beep sound to prompt self-check, battery type report, and operation allowed in sequence (as shown in 

the  table  below).  If  the  sound  of  the  motor  is  incomplete  when  the  ESC  starts,  inspect  the  ESC  and  the 

equipment connected. 

 

Motor Sound 

ESC status 

Tone beep (Do-Re-Mi) 

Self-check finished 

Short beep 

Battery type report 

Long beep 

Operation allowed 

 

Note

:  There  are  three  consecutive  tones,  Do-Re-Mi,  in  tone  beep  state  of  the  motor.  The  number  of  short 

beeps varies according to the battery type. You need to set the Jumper cap 3 first to match the type of the 

battery used. When using a non-lithium battery, the short beep will only be heard once. When using a lithium 

battery, the number of short beeps is determined by the number of the battery cells (For example, when 4S 

lithium battery is connected to this ESC system, 4 short beeps will be heard). 

 

5.2 Indicator light 

When the power light and status light of this ESC system are always on, the ESC is operating normally. If the 

power light or status light is flashing and there is no sound from the motor, you can refer to the following table 

to confirm the current system states: 

 

Indicator light 

Prompt mode 

System states 

Green light 

Always on 

Battery self-test failed 

Flash once every 0.2 second 

Battery over-voltage warning 

Flash once every second 

Battery under-voltage warning 

Red light 

Flash once every 0.2 second 

System voltage self-test failed 

Summary of Contents for COOL 9030

Page 1: ...ehicles Drift Cars Crawlers Trailers Bait Boats Rescue Boats Surveying Boats Note This manual only introduces the basic usage of RadioLink COOL 9030 brushed ESC For more information such as tutorials and FAQ please access to RadioLink website www radiolink com or send mail to after_service radiolink com cn ...

Page 2: ... 3 1 1 COOL 9030 Overview 3 1 2 Specifications 4 Part 2 Connection of COOL 9030 5 2 1 Power Input 5 2 2 Motor output 6 2 3 Signal input 7 Part 3 Throttle calibration 8 Part 4 Usage of Jumper Cap 9 Part 5 ESC status 10 5 1 Motor sound 11 5 2 Indicator light 11 5 3 Mixed prompt of motor and light 12 Thanks 12 ...

Page 3: ...nected for a long time without use the battery will eventually be completely discharged which will cause the malfunction of the battery or ESC RadioLink is not responsible for any damage caused by incorrect operation Part 1 Introduction of COOL 9030 1 1 COOL 9030 Overview Power input The power input of the ESC is connected to the power supply At the same time the voltage range of connected power s...

Page 4: ... input power supply and the output voltage of BEC Details will be introduced later LED light description Power light The power light is used to indicate the current self check and power supply status of the ESC system The color of the light is green Details will be introduced later Status light The status light is used to indicate the current self check and operating status of the ESC system The c...

Page 5: ...There is no positive or negative connection between the brushed motor and the ESC If the motor turns incorrectly you can directly change the direction of the motor through the servo phase in the menu of the transmitter or exchange the connection of the two motor output cables of ESC Make sure the right connection and good contact between the motor and the ESC Connection to the battery The battery ...

Page 6: ...rotection state and the battery voltage rises back to the half power protection value the system will exit the under voltage protection state Then the system will return to normal operation and the normal output control of the motor is restored Half power protection It is half power output protection state When the voltage of the input power supply is lower than the value the ESC will reduce the o...

Page 7: ...oncrete cases to prevent the ESC and motor from being damaged or even battery damage accidents 2 3 Signal input The signal input the throttle signal input of this brushed DC ESC can only identify the PWM signal output by a single channel of the receiver The signal with multiple channel codes such as PPM signals S BUS signals etc cannot be recognized At the same time the characteristics of the PWM ...

Page 8: ...ote controller such as servo output ratio and servo midpoint value etc Calibrate the throttle at this time so that the ESC can be adjusted to the signal output of the receiver to achieve the expected effects COOL 9030 is a two way ESC so the throttle calibration method is the same as that of the common two way ESC The specific steps are as follows ESC Calibration Method Preparation Connect the ESC...

Page 9: ... output voltage Jumper cap 1 and 2 are used to set the operation mode of the ESC Jumper cap 3 is for battery type and jumper cap 4 for BEC output voltage The different states of the 4 sets of jumper caps will correspond to the different operation modes of the ESC Choose the operation mode you need determine the type of the battery you use and the requirements for the BEC Then refer to the followin...

Page 10: ...Type When using different types of batteries change the state of Jumper cap 3 to make the battery type match the actual battery Insert Jumper cap 3 when using a lithium battery and remove Jumper cap 3 when using a non lithium battery Wrong state of Jumper cap 3 may cause serious over discharge of the battery and damage the battery Be sure to check Jumper cap 3 to confirm the battery type of the ES...

Page 11: ...check battery type report and operation allowed in sequence as shown in the table below If the sound of the motor is incomplete when the ESC starts inspect the ESC and the equipment connected Motor Sound ESC status Tone beep Do Re Mi Self check finished Short beep Battery type report Long beep Operation allowed Note There are three consecutive tones Do Re Mi in tone beep state of the motor The num...

Page 12: ...ht are as follows Motor sound and red indicator light System state Four consecutive short beeps System high temperature warning Above 85 Flash once every 0 2 second Three consecutive short beeps System low temperature warning Below 40 Flash once every 0 4 second One short beep Throttle signal loss Flash once every 0 6 second Two consecutive short beeps Abnormal throttle signal Flash once every 0 8...

Reviews: