Radiolink Electronic Ltd
9
3.3.2 BASIC Menu
There are six parameters to setup including ”REV”“SUB”“EPA-L”“EPA-R”“F/S”“DELAY”
REV:
Defines the relationship between the transmitter controls and the receiver output for channels with
options of NORM and REV. Make sure to check all servos move to the correct direction as wish under control.
Make sure to check all servos move to the correct direction under control.
Note
If programmable mix control function is used to control several servos for fixed wing/gliders,
eg. V-TAIL mix control, make sure to set the phase to avoid possible confusion.
SUB:
Makes small changes or corrections to the neutral position of each servo. The default is 0 setting by
factory setting. That is, no SUB-TRIM. The range is from -120 to +120 and can be modified with actual need.
It’s advised to center the digital trims before making SUB-TRIM changes, and keep all of the SUB-TRIM
values as small as possible. In order to restrict the servo travel range, the recommended procedure is as
follows:
•
Measure and record the desired surface position;
•
Zero out the SUB-TRIM ;
•
Mount servo arms and linkages so that the control surface’s neutral is as correct as possible;
•
Modify with SUB-TRIM small range value to make fine corrections.
EPA-L &EPA-R
: Sets the range of each channel in percentage. The most flexible version of travel
adjustment is available. It independently adjusts each end of each individual servo’s travel, rather than one
setting for the servo affecting both directions. The default value is 96.
F/S:
Sets responsive action of model in case of signal loss or low Rx voltage(in percentage).
Each channel can be set independently.
•
The NOR (normal) setting holds the servo in its last commanded position.
•
The F/S (Fail Safe) function moves each servo to a predetermined position.
Note
The setting of the throttle F/S also applies to the low battery voltage. F/S value 0 means throttle stick at the
lowest point while 50 means at the central point.