RadioLink Electronic Limited
13
3.2.2 SBU-TRIM
Makes small changes or corrections to the neutral position of each servo. The default is 0 setting by
factory setting. That is, no SUB-TRIM. The range is from -100 to +100 and can be modified with actual
need.
The interface of parameter setup APP on phone.
The interface of parameter setup software on computer.
This function is used to set the neutral position of the servo, not to set the servo surface to be
horizontal.
This function is used to set the neutral position of the servo, not to set the servo surface to be
horizontal.
So, the recommended steps are as follows:
•
Zero out the SUB-TRIM when the servo is not connected to servo surface, and adjust the neutral
position of the servo through SUB-TRIM.
•
Zero out the SUB-TRIM.
•
Mount servo arms and linkages so that the control surface
’
s neutral is as correct as possible.
•
Modify with SUB-TRIM small range value to make fine corrections.