background image

D2412 Installation Manual

Page 2

8/11/97   P/N 35115B

© 1997 Radionics

Notice

The material and instructions covered in this manual have been
carefully checked for accuracy and are presumed to be reliable.
However, Radionics, Inc. assumes no responsibility for inaccura-
cies and reserves the right to modify and revise this manual
without notice.

If a discrepancy is found in this documentation, please mail a
photocopy of the corrected material to:

Technical Communications
c/o Radionics, Inc.
1800 Abbott Street
P.O. Box 80012
Salinas, CA 93912-0012

© 1997 Radionics, Inc. Salinas, CA, U.S.A.       All rights reserved.

FCC Notice
Part 15

This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency
energy, and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of
the following measures:

•  Re-orient or relocate the receiving antenna.
•  Increase the separation between the equipment and the

receiver.

•  Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected.

•  Consult the dealer or an experienced radio/TV technician for

help.

Part 68

This equipment complies with Part 68 of FCC rules. A label
contains, among other information, the FCC registration number
and ringer equivalence number (REN).

Radionics registered the D2412 Control/Communicator for
connection to the public telephone network using an RJ31X jack.

Use the ringer equivalence number (REN) to determine the
number of devices you can connect to the telephone line.
Excessive RENs on the telephone line may result in devices not
ringing in response to an incoming call. In most, but not all areas,
the sum of the RENs should not exceed five (5). Contact the
telephone company to determine the maximum REN for the
calling area.

If the D2412 Control/Communicator causes harm to the telephone
network, the telephone company will notify you in advance. If
advance notice isn’t practical, the telephone company will notify
the customer as soon as possible. Also, you will be advised of
your right to file a complaint with the FCC if you believe it is
necessary.

The telephone company may make changes in its facilities,
equipment, operations, or procedures that could affect the
operation of the D2412. If this happens, the telephone company
will provide advance notice in order for you to make the necessary
modifications to maintain uninterrupted service.

If you experience trouble with the D2412 Control/Communicator,
please contact Radionics Customer Service for repair and/or
warranty information. If the trouble is causing harm to the
telephone network, the telephone company may request that you
remove the D2412 from the network until the problem is resolved.
User repairs must not be made. Doing so voids the user’s
warranty.

Do not install the D2412 on public coin service provided by the
telephone company. Connection to Party Line service is subject to
state tariffs (contact your state public utilities commission for
information). You must supply the local telephone company with
the following information at their request:

•  The line you are going to connect the panel to.

•  Make (Radionics), model (D2412), and serial number of the

panel.

•  FCC registration number and ringer equivalence for the

panel.

FCC Registration Number:  ESVUSA-30727-AL-E
Ringer Equivalence:  0.3B
Service Center in USA:  Radionics, Inc.

1800 Abbot Street
P.O. Box 80012
Salinas, CA 93912-0012
(800) 538-5807

Notice

The Industry Canada label identifies certified equipment. This
certification means that the equipment meets certain telecommu-
nications network protective, operational, and safety require-
ments. Industry Canada does not guarantee the equipment will
operate to the user’s satisfaction.

Before installing this equipment, users should ensure that it is
permissible to be connected to the facilities of the local telecom-
munications company. The equipment must also be installed using
an acceptable method of connection. The customer should be
aware that compliance with the above conditions may not prevent
degradation of service in some situations.

Repairs to certified equipment should be made by an authorized
Canadian maintenance facility designated by the supplier. Any
repairs or alterations made by the user to this equipment, or
equipment malfunctions, may give the telecommunications
company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical
ground connections of the power utility, telephone lines and
internal metallic water pipe system, if present, are connected
together.

Caution:  Users should not attempt to make such connections
themselves, but should contact the appropriate electric inspection
authority, or electrician, as appropriate.

www.PDF-Zoo.com

firealarmresources.com

Summary of Contents for D2412

Page 1: ...8 11 97 P N 35115B 1997 Radionics D2412 Control Communicator Installation Manual www PDF Zoo com firealarmresources com ...

Page 2: ...so you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the D2412 If this happens the telephone company will provide advance notice in order for you to make the necessary modifications to maintain uninterrupted service If you ex...

Page 3: ... Checking Continuous Current Draw 8 External Relays 8 Connect the Points 8 Point 1 8 Points 2 to 6 9 Point Wiring Diagram 9 Point Expanders Wired or RF 10 Make the Telephone Connections 10 Power Up 10 Program the Panel 10 Unlock the Standby Switch 10 Fill out the Delay Chart 11 Test the System 11 Detailed Description 11 Primary AC Power Circuit 11 Secondary DC Power 11 Power Outputs 12 Telephone 1...

Page 4: ...07032 000 D206 Keypad Each D206 includes the following D206 Keypad Installation Sheet 31946 Security System User s Guide 71 07117 000 Getting Started with Your Security System 71 07372 000 Three wire data cable assembly 15 07032 000 D220A Keypad Each D220A includes the following D220A Keypad Installation Sheet 74 07363 000 User s Reference Card 71 05432 011 Security System User s Guide 71 07374 00...

Page 5: ...istance before installing smoke detectors Short the end of line resistor before metering the wire Resistance on the sensor loops for Points 2 to 6 must be less than 100Ω with the end of line resistor shorted and the detection devices connected Maximum wire length for the transformer is 50 feet 18 AWG stranded Maximum wire length for all keypads and point expanders combined is 500 feet 22 AWG EMI E...

Page 6: ...lug the connector on the positive red battery wire to the positive side of the battery Charge the Battery as You Work Lock the Standby Switch Locking the pin in the standby position allows you to charge the battery as you install the detection devices and keypads Lock the pin down now See Figure 2 With the Standby Switch locked down the panel deacti vates the external relay outputs suppresses repo...

Page 7: ...n NSC This total must be less than 140mA 2 Subtract the NSC current required calculated in step 1 from the Primary Alarm Current 860mA The difference is the Alarm Current available for the Alarm Output terminals In formula format Primary Alarm Current NSC current required Alarm Current available Keypads Terminals 6 7 and 8 Data and Aux You can connect a combination of up to eight keypads and two t...

Page 8: ...t 1 on the D2412 is a powered supervised point The panel monitors the Point 1 sensor loop for normal shorted or open conditions Programming determines how the panel responds to those conditions See the Program Entry Guide Terminal 11 provides positive voltage to 2 wire detection devices Terminal 12 the loop return is isolated from earth ground The Keypad Reset function interrupts power to this sen...

Page 9: ...oute the power for the detectors through a D133 or D134 Relay Module The relay module must be connected to one of the panel s external relay outputs programmed for the reset function See RELAYS in the Program Entry Guide for programming instructions Heat Detectors and Other Dry Contact Initiating Devices Connect any number limited by the Authority Having Jurisdiction Burglary Devices Connect any n...

Page 10: ...After installation confirm that the panel seizes the line acquires dial tone reports correctly to the receiver and releases the phone line to the in house phone system Phone Cord Connect the flying leads of the D160 or D164 Phone Cord to the panel as shown in Figure 7 Connect the modular end to the RJ31X Power Up Connect the battery and then plug in the transformer Leave the Standby Switch locked ...

Page 11: ...e ground connection Make sure the panel s ground terminal is connected to a proper ground AC Power Failure The panel indicates an AC power failure when power at the terminals labeled 16 5VAC is missing for 60 seconds The AC Fail Buzz Rpt program item sets the panel s response to detected AC failure The panel indicates an AC power restoral 60 seconds after power restores to the terminals labeled 16...

Page 12: ...add one or more D8132 Battery Charger Power Supply Modules for the number of keypads you want to use Figure 10 shows the D8132 powering keypads in a stand alone configuration For UL Certificated accounts use a UL listed power supply The D8132 is not UL listed as a stand alone power supply for fire and burglary applications D2412 and D8132 or other power supply must share COMMON Note that Figure 10...

Page 13: ... and off Connect the keyswitch to any point sensor loop You can use the external relay outputs and D133 or D134 Relay Modules to activate arming status lights or keyswitch arming stations See the Relays section in the Program Entry Guide Programming See the POINT CODES Group in the Program Entry Guide for the correct programming for points used for keyswitches Installation Connect the end of line ...

Page 14: ...uctions You must use a 12 VDC option for the Easikey installation See Easikey Installation and Operation Instructions Easikey is not for use in UL installations Connect the Easikey door controller to the panel using a D133 Relay Module as shown in Figure 13 Make certain to connect the common for the Easikey s 12 VDC supply to the terminal labeled Aux on the panel Figure 13 Keyswitch www PDF Zoo co...

Page 15: ...etermine suitability When using four wire smoke detectors install a suitable power supervision unit according to the manufacturer s instructions Use the D133 or D134 Relay Module to provide reset capability In fire applications with one 7 0Ah 12 VDC battery the panel supports an auxiliary output of 140mA it supports a total combined continuous and alarm current draw during alarm conditions of 1 0A...

Page 16: ...otection must be provided The D2412 control panel is suitable for Central Station Grade C applications It is suitable for Central Station Grade B applications when the Model D2412 DACT unit is installed with a UL listed Local sounding device Also suitable for Central Station Mercantile Grade AA applica tions when installed with the Model D8122 derived channel subscriber terminal unit The D2412 con...

Page 17: ...ndby plus four minutes 067 hrs of alarm operation at the end of the 24 hour period You must use battery ampere hour Ah calculations to verify compliance The formula in the next column includes a 10 contingency factor for depletion of battery capacity with age NFPA 72 Chapter 2 Ampere Hour Calculation Formula Total B ___ x 24 Hrs Total C ___ x 067 Hrs 10 Contingency Total Ah required Total Ah requi...

Page 18: ..._ D222 _____ 30 _____ 30 _____ 140 _____ D223 _____ 30 _____ 30 _____ 140 _____ D208RF _____ 50 _____ 50 _____ 50 _____ D216RF _____ 50 _____ 50 _____ 50 _____ _______ _____ ___ _____ ___ _____ ___ _____ _______ _____ ___ _____ ___ _____ ___ _____ _______ _____ ___ _____ ___ _____ ___ _____ _______ _____ ___ _____ ___ _____ ___ _____ _____ Total A _____ Total B _____ Total C _____ If Total A excee...

Page 19: ... Keypad D205 Keypad D206 Keypad D220A Keypad D222 Keypad D223 Keypad D204RF Keypad Keychain Keypad 60 606 319 5 Keyswitch Easikey Compatible Enclosures D2203 Standard Enclosure D8103 Universal Enclosure D8109 Fire Enclosure D8108A Attack Resistant Enclosure Compatible Accessories See the Radionics Product Catalog for complete list D126 12V 7 Ah Rechargeable Battery D127 Reversing Relay D133 Relay ...

Page 20: ...ive output for continuously powered devices 1 0A at 10 2 to 13 9 VDC Protected against overcurrent by self resetting device 8 Aux Aux Power Negative common for Aux Power and Relay Outputs 9 Ext1 External Relay 1 Connect D133 or D134 relay for Form C Dry Contact 10 Ext2 External Relay 2 Connect D133 or D134 relay for Form C Dry Contact 11 1 Positive Point 1 Positive Power for Point 1 Switched for s...

Reviews: