D9000/D7000 Series Operation & Installation Manual
Page 53
74-07692-000-C 4/97
5.
During the Service Walk Test you may want
to see the points that remain untested. When
point text is displayed, press "ESC". The
display shows
## PTS TO TEST. Press the
"ESC" key.
VIEW UNTESTED ? is
displayed. Press ENT.
## PTS UNTESTED is
displayed. Press NEXT to see a list of the
points that have not yet been tested. Move
through this list by pressing the NEXT key.
To resume the Service Walk Test, press
"ESC".
## PTS UNTESTED is displayed.
Press "ESC".
## PTS TO TEST is displayed.
Resume testing points. To end the Service
Walk Test, press "ESC" twice.
6.
After testing the last point,
0 PTS TO TEST
displays. Press "ESC". The display
momentarily shows
ALL PTS TESTED
before returning to idle text.
Note: The Service Walk Test, when performed on
a D7412 or D7212, cannot display “0 points to
test” as it is physically unable to connect to the
second POPEX module (used for points 129-
247).
Automatic time-out returns the system to idle
text: If there is no point or Command Center
activity for 20 minutes, the walk test ends
automatically. The Command Center returns to
idle text.
Figure 21: Service Walk Test Flow Chart
EN T
VIEW U NTE STED ?
E NT
# PTS U NTESTED
NEX T
SERVICE WALK ?
246 PT S TO TEST
245 PTS TO TE ST
244 PTS TO TES T
POINT TEXT
POINT TEXT
POINT TEXT
1 PTS TO T EST
0 PT S TO TEST
POIN T TEXT
Te st a de vice
(Tex t disp lays 60 se c on ds )
Te st a de vice
(Te xt dis play s 60 s ec ond s)
Te st a de vice
Tes t a d ev ic e
IDLE TEXT
ESC
ESC
ESC
ESC
www.PDF-Zoo.com