D7212 Installation and Troubleshooting Quick Reference

Page  6

74-06914-000-A 8/93

© 1993 Radionics

Troubleshooting Continued

Symptom

Diagnosis

Remedy

All off-board points are
MISSING.

Short on Aux Power,
terminal 3.

Terminal 3 shares a common circuit breaker.
Check wiring and devices connected to this
terminal for shorts or grounds.

Problems with Points 

(Continued from page 5)

Problems with Command Centers

Symptom

Diagnosis

Remedy

Command centers
show erratic behavior.  

For example, the pip
that confirms you
pressed a key
"echoes" or the back
lighting flashes off and
on.

A supervised address
has been entered in
more than one
command center.

Entering a supervised address in more than
one command center causes erratic behavior.  

Use a supervised address in one command
center only.  

One or more of the
keys is stuck under
the faceplate

Press each of the keys on the command
center to be certain none of them is stuck.

Data connections
(yellow and green
wires) on one or more
command centers are
reversed, or only one
wire is connected.

Check to be sure that the yellow and green
data wires are correctly connected at all
command centers.

NO AUTHORITY
displays at command
center when you enter
your passcode to
perform a function.

Check the 

User Interface  section of the program to be sure the

function is enabled for Authority Level assigned to the passcode in the
Passcode Work sheet  section of the program.

Check the 

Passcode  Worksheet  section of the program to be certain

the passcode is assigned to the area where you are attempting to
perform the function.

Check the 

Passcode  Worksheet  section of the program to see if the

passcode is restricted by a user window.

Check the 

Area Parameters  section of the program to be certain the

area you are attempting to perform the function in is turned on.

Summary of Contents for D7212

Page 1: ...rminal Description 12 Introduction This reference contains the very basic information a trained installer needs to install and troubleshoot a D7212 system See the D7212 Operation and Installation Manu...

Page 2: ...are AREA IS ON AREA IS OFF Follow the procedure below to toggle between custom and default idle text 1 Ensure the command center is at idle text 2 Press COMMAND 5 7 3 The display will change to defau...

Page 3: ...connected to same ZONEX as a D8125 Connect only one OctoPOPIT with switch 12 ON to ZONEX If ZONEX is connected to a D8125 turn switch 12 OFF for all OctoPOPITs connected to that terminal POPIT is not...

Page 4: ...Faulted points do not generate alarms or troubles as programmed Command 47 pressed at the time the alarm or trouble was generated The D7212 ignores input from all points in the same area programmed fo...

Page 5: ...FOR TYPICAL BURGLAR ALARM APPLICATIONS SUITABLE FOR VALVE TAMPER AND OTHER TYPES OF EXTINGUISHING SYSTEM SUPERVISION TYPICAL INITIATING DEVICES ARE DOOR CONTACTS NO NC FLOOR MATS MOTION SENSORS GLASS...

Page 6: ...keys is stuck under the faceplate Press each of the keys on the command center to be certain none of them is stuck Data connections yellow and green wires on one or more command centers are reversed...

Page 7: ...is plugged securely into the D5200 programmer 3 Check each conductor in the data power cord for continuity AC induction through the on board point sensor loops the DATA BUS or the ZONEX BUS 1 Verify...

Page 8: ...s 1 and 8 5 Verify that all telephones are on hook Leaving a telephone on hold after the other party hangs up creates an off hook condition Verify that no phones are on hold If completing the steps ab...

Page 9: ...y signal for all ten attempts to reach the receiver Calls are not reaching the receiver 1 Verify that correct prefixes and phone numbers for the receiver have been programmed into the D7212 2 Verify t...

Page 10: ...7 8 SWITCHED AUX POWER Supplies up to 1 4 Amps at 10 0 VDC to 13 9 VDC Use terminal 9 for common Programmed as Relay C Continuous output interrupted by CMD 47 or alarm verification Shares circuit bre...