D7212 Installation and Troubleshooting Quick Reference

Page  8

74-06914-000-A 8/93

© 1993 Radionics

Communications Failure

Follow the 

Phone Line Trouble  procedure to verify that there is no problem with the phone lines

at the D7212  installation. If the phone lines are good, monitor the lines (preferably at the
receiver) for the symptoms listed below.

Phone Line Trouble

Phone line problems can result in the D7212 going into Communications Failure.

Symptom

Diagnosis

Remedy

SERVC PH LINE #1
(or 2 if two lines are
used) appears

 

in

command center
display.

D7212's phone line
monitor detects a
phone line as faulted.

1.

Verify that the telephone cord is correctly
connected to the RJ31X and the D7212.

2.

Verify the Ground Start Jumper is in the
correct position.

3.

If using a ground start phone line, verify
D136 relay is in socket K6/J5.

4.

Verify that the RJ31X jack is wired
correctly. The incoming phone line must
be wired to terminals 4 and 5. The in-
house phone system must be wired to
terminals 1 and 8.

5.

Verify that all telephones are on-hook.
Leaving a telephone on hold after the
other party hangs up creates an off-hook
condition. Verify that no phones are on
hold.

If completing the steps above does not restore
the phone line, meter the phone lines. You
should meter at least 7.5 VDC when the line is
idle (on-hook). You should meter at least 13
mA of current when the line is active (off-hook).
If your readings are below the minimum values,
contact your telephone company repair
service.

Symptom

Diagnosis

Remedy

The receiver answers
the call and provides
an initial “handshake”
acknowledgment, but
does not
acknowledge the
D7212's report
transmission with a
“kiss-off”
acknowledgment .

The receiver is not
compatible with the
D7212's transmission
format.

Verify that the receiver is compatible with the
format the D7212 is using (either BFSK or
Modem II). See 

Phone  in the D7212 Program

Entry Guide (74-06915-000).

Modem II requires D6500 MPU and Line Card
EPROM revision 6.00 or higher.

Noisy phone lines are
interfering with report
transmission.

Try making a voice call to the receiver on the
line to verify the noisy condition. It may be
necessary to have the phone company check
the lines.

Summary of Contents for D7212

Page 1: ...rminal Description 12 Introduction This reference contains the very basic information a trained installer needs to install and troubleshoot a D7212 system See the D7212 Operation and Installation Manu...

Page 2: ...are AREA IS ON AREA IS OFF Follow the procedure below to toggle between custom and default idle text 1 Ensure the command center is at idle text 2 Press COMMAND 5 7 3 The display will change to defau...

Page 3: ...connected to same ZONEX as a D8125 Connect only one OctoPOPIT with switch 12 ON to ZONEX If ZONEX is connected to a D8125 turn switch 12 OFF for all OctoPOPITs connected to that terminal POPIT is not...

Page 4: ...Faulted points do not generate alarms or troubles as programmed Command 47 pressed at the time the alarm or trouble was generated The D7212 ignores input from all points in the same area programmed fo...

Page 5: ...FOR TYPICAL BURGLAR ALARM APPLICATIONS SUITABLE FOR VALVE TAMPER AND OTHER TYPES OF EXTINGUISHING SYSTEM SUPERVISION TYPICAL INITIATING DEVICES ARE DOOR CONTACTS NO NC FLOOR MATS MOTION SENSORS GLASS...

Page 6: ...keys is stuck under the faceplate Press each of the keys on the command center to be certain none of them is stuck Data connections yellow and green wires on one or more command centers are reversed...

Page 7: ...is plugged securely into the D5200 programmer 3 Check each conductor in the data power cord for continuity AC induction through the on board point sensor loops the DATA BUS or the ZONEX BUS 1 Verify...

Page 8: ...s 1 and 8 5 Verify that all telephones are on hook Leaving a telephone on hold after the other party hangs up creates an off hook condition Verify that no phones are on hold If completing the steps ab...

Page 9: ...y signal for all ten attempts to reach the receiver Calls are not reaching the receiver 1 Verify that correct prefixes and phone numbers for the receiver have been programmed into the D7212 2 Verify t...

Page 10: ...7 8 SWITCHED AUX POWER Supplies up to 1 4 Amps at 10 0 VDC to 13 9 VDC Use terminal 9 for common Programmed as Relay C Continuous output interrupted by CMD 47 or alarm verification Shares circuit bre...

Reviews: