Installation Instructions

D9560CM Ceiling Mount

Passive Infrared Intrusion Detector

1.0 General Description

The D9560CM is a high performance passive infrared intrusion
detector. It is equipped with advanced PIR detection and
supervision circuits and is designed to provide an alarm
condition upon detection of an intruder passing through its area
of coverage.

Employing balanced dual-opposed sensing elements, the
D9560CM passive infrared (PIR) detector makes use of the fact
that all objects give off (transmit) infrared energy, and that the
warmer the object is, the greater the amount of infrared given
off. The D9560CM uses PIR receiver technology designed to
detect the CHANGE in infrared energy caused when a target of
a different temperature from a stable background passes
through its field of coverage.

The coverage pattern consists of sensor zones arranged to form
a circular coverage pattern.

Using Motion Analyzer II circuitry, the detector must first see a
change in infrared energy in one finger followed by a change of
energy in the remaining finger. Therefore, disturbances that
occur in only one finger do not constitute motion and are
ignored. This “catch sensitivity” may be changed in the field by
the installer to provide the degree of sensitivity required by the
installation.

Self-test and supervision circuits provide reliable, uniform
operation in a wide variety of installation environments. The
result is a highly advanced detector offering superior perfor-
mance with freedom from false alarms.

2.0 Specifications

• Input Power:   6.0  to 15.0 VDC; 18 mA nominal @ 12 VDC.

38 mA maximum.

• Standby Power:  There is no internal standby battery. Unit is

intended to be connected to DC power sources capable of
supplying standby power in the event primary power fails.
Eighteen mA-H required for each hour of standby time
needed. 

Four hours (72 mA-H) minimum are required for U. L.

Certificated installations.

• Coverage:  360

°

 by 60 ft. (18.3 m) diameter coverage when

mounted on 8 to 18 ft. (2.4 to 5.5 m) high ceilings. Pattern
consists of 64 zones grouped into 16 barriers, with one
additional zone looking straight down from the unit (sabo-
tage). Each barrier is 30 ft. (9.2 m) long and 4.4 ft. (1.3 m)
wide at 30 ft. (9.2 m). Choice of two optical modules depend-
ing on ceiling height.

Note:

For U. L. Listed Requirements, the coverage is 360

°

 by

54 ft. (16.5 m) when mounted from 10 to 13 ft. (3.1 to 4.0
m) using the AR8-13 Array and when mounted from 15 to
18 ft. (4.6 to 5.5 m) using the AR13-18 Array.

• Sensitivity:  Field selectable for Standard, Intermediate, or

High.

• Alarm Relay:  Silent operating Form “C” reed relay. Contacts

rated 3 Watts, 125 mA, 28 VDC maximum for DC resistive
loads, and protected by a 4.7 ohm, 1/2 Watt resistor in the
common “C” leg of the relay. 

Do not use with capacitive or

inductive loads (such as relays or magnetic locks).

• Tamper:  Normally Closed (with cover in place) tamper

switch. Contacts rated at 3 Watts, 28 VDC, 125 mA maxi-
mum. .

• Trouble Output:  A solid state open collector conducts to

terminal 1 (-) when the detector is in a trouble condition.
Maximum current load is 25 mA.

• Temperature:  The storage and operating range is -20

°

 to

+120

°

F (-29

°

 to +49

°

C). 

For U. L. Listed Requirements, the

range is +32

°

 to +120

°

F (0

°

 to +49

°

C).

• Sonalert™ Connector:  Using a Sonalert™ type sounder

(low voltage) will provide an audible tone when the unit is in
alarm. 

Use of the sounder is intended only as an aid for walk

testing during installation.

Sonalert™ is a trademark of Mallory.

• Options:  TC6000 Test Cord.

• U. S. Patent Numbers:  #4,764,755 and #5,083,106.

Mounting Base

REAR WIRE

ENTRANCE

WIRE

TIE-DOWNS (2)

TERMINAL

STRIP

INTERFACE

PINS

MOUNTING

SLOTS (4)

18

Top View of Enclosure

with Cover Removed

AR8-13

AR8-13

ALARM/TEST LED

INDICATOR (3)

SOUNDER

NOISE

VOLTAGE

CONFIGURATION
SWITCHES

COVER

TAMPER

MODULE TABS (2)

OPTICAL
MODULE

ON

OFF

TEST LEAD

CUTOUT

D9560CM Installation Instructions

Page 1

© 1996  Radionics

P/N 31367C

Radionics

Summary of Contents for D9560CM

Page 1: ...hours 72 mA H minimum are required for U L Certificated installations Coverage 360 by 60 ft 18 3 m diameter coverage when mounted on 8 to 18 ft 2 4 to 5 5 m high ceilings Pattern consists of 64 zones grouped into 16 barriers with one additional zone looking straight down from the unit sabo tage Each barrier is 30 ft 9 2 m long and 4 4 ft 1 3 m wide at 30 ft 9 2 m Choice of two optical modules depe...

Page 2: ...o the two optical module tabs For ceilings between 13 and 18 ft 4 0 and 5 5 m high use the optical module marked AR13 18 To replace an optical module push the optical module tabs towards the center until the module snaps free of the circuit board Holding the new module by the tabs snap the new module into place 0 10 10 20 20 30 Feet 30 0 10 15 AR13 18 SIDE VIEW Cross Section of 2 Opposite Zones 0 ...

Page 3: ...r pin is positive with respect to either outside pin outside pins are common Sonalert is a trademark of Mallory Place the cover on the unit and twist lock it clockwise into place Note Be sure the TC6000 and Sonalert leads are dressed through the cutout Apply power to the unit Wait at least two minutes after applying power to start walk tests Note Walk testing should be done across the coverage pat...

Page 4: ...ion of the screw holes 11 2 Optical Module Masking Peel off masks are provided with the unit for each segment of the optical module to allow for customized coverage or to block out areas or objects that may cause thermal distur bances The mask is self adhesive and pre cut in the shape of the optical module To block out a particular zone or group of zones peel off a section of the mask that corresp...

Reviews: