47
Intr
oduction
Ins
tallation
Oper
ation
Configur
ation
Tapacul
o 365
Maint
enanc
e
Cus
tomer Servic
e
Inf
ormation
Or
der Lis
t
About this Manual
HT
TP R
adionode
Pr
ot
oc
ol V2
The first two of the five tags are mandatory, whereas the remaining
three tags are options, subject to change according to the server's
reply.
●
ack
ack
: Processing outcome (
ok
ok
or
error
error
)
●
timestamp
timestamp
: Current time of the server in UNIX timestamp
format
●
offset-ch1
offset-ch1
: Calibration Value of Channel 1
●
offset-ch2
offset-ch2
: Calibration Value of Channel 2
●
sample-mode
sample-mode
: Measurement and Transfer Intervals.
If this tag’s value is "3," the measurement interval changes
to 5 minutes and the transfer interval to 20 minutes. See the
following table:
1
2
3
4
5
6
7
8
9
10 11 12 13
Measurement
interval
1 m 1 m 5 m 5 m 10 m 10 m 10 m 10 m 20 m 30 m 10 s 10 s 10 s
Transfer
Interval
10 m 5 m 20 m 10 m 10 m 30 m 20 m 60 m 40 m 60 m 10 s 30 s 60 s
sample-mode
sample-mode
Note that when setting a tag to a
value greater than 10, setting measurement and
transfer intervals in seconds may cause rapid battery
depletion.