RADIUS
Product
Description
PDR 121
iom_pdr121_04_r02.doc
Rev 02
Page 45 (67)
12 Configuration
12.1 Equipment
Configuration of the PDR 121 is performed via the Rbus interface using the RADIUS ProgInt cable
and a standard communication program, like Windows HyperTerminal. The terminal program
needs to be configured to 57600 bps, 8 data bits, no parity and 1 stop bit.
12.2 Getting Started
Follow the procedure below to enter the PDR 121 configuration menus.
1. Ensure that the PDR 121 has 12 VDC supplied.
2. Connect the serial DB-9 connector of the ProgInt cable to the PC.
3. Connect the modular connector of the ProgInt cable to the PDR Rbus jack.
4. Start the terminal program on the PC.
5. Select an available PC COM port.
6. Configure the communication settings to 57600, 8 N 1.
7. Press ‘C’ (capital) to enter the PDR 121 configuration menus.
Note!
After configuration, “Exit Configuration” must be chosen or else the PDR 121 will remain in
the configuration mode and will not operate in the “normal mode”.
If the PDR is powered up after connected to a terminal program, the following information will be
downloaded into the connected PC:
Note!
If the PDR 121 was powered up before connected to the terminal program, you need to
press ‘C’ to enter the configuration menus.
Packet Data Radio - PDR121
Copyright RADIUS Sweden AB
Software: PDR121S v1.0 Build Sep 15 2004
ArtNo:303062-4 SwNo:50 HwNo:18
Executing
Press C to enter configuration mode