RADIUS
Product
Description
PDR221
iom_pdr221_04_r02.doc
Rev 02
Page 45 (60)
12 Configuration
12.1 Equipment
Configuration of the PDR221 is performed via the Rbus interface using the RADIUS ProgInt cable
and a standard communication program, like Windows HyperTerminal. The terminal program
needs to be configured to 57600 bps, 8 data bits, no parity and 1 stop bit.
12.2 Getting Started
Follow the procedure below to enter the PDR221 configuration menus.
1. Ensure that the PDR221 has 12 VDC supplied.
2. Connect the serial DB-9 connector of the ProgInt cable to the PC.
3. Connect the modular connector of the ProgInt cable to the PDR Rbus jack.
4. Start the terminal program on the PC.
5. Select an available PC COM port.
6. Configure the communication settings to 57600, 8 N 1.
7. Press ‘C’ (capital) to enter the PDR221 configuration menus.
Note!
After configuration, “Exit Configuration” must be chosen or else the PDR221 will remain in
the configuration mode and will not operate in the “normal mode”.
If the PDR is powered up after connected to a terminal program, the following information will be
downloaded into the connected PC:
Note!
If the PDR221 was powered up before connected to the terminal program, you need to press
‘C’ to enter the configuration menus.
Packet Data Radio - PDR221
Copyright RADIUS Sweden AB
Software: PDR221S v1.0 Build Jul 14 2004
AN:124356-1 SwNo:51 HwNo:18
Executing
Press C to enter configuration mode