Page 20 of 22
IN063 Rev.D 0120
3 Saber Way, Ward Hill, MA 01835 | radonaway.com
Symptom
Solution
No water in house
Water not entering system
Jet Pump not functioning
Pressure in tank is less than 40 PSI
Low water flow at faucets
Blower not running
Blower does not stop running
Loud banging when solenoids shut
Pump is short cycling
Pump won't shut off
Solenoids chatter when closing
System running dry
• Check power: Switch in on position, circuit breaker at panel in on
position, fuses in control panel intact.
• Check pressure in tank. If below the proper settings, reset the pump
as described in System Start-up (p. 17).
• Bypass System. If there is still no water, main well pump may not
be functioning.
• Check on/off float for proper operation. Replace if necessary.
• Check solenoids for proper operation. Replace if necessary.
• Check float switches for proper operation. Replace if necessary.
• Check sediment strainer and/or filter (if applicable) and clean if necessary.
• Check fuse in control panel.
• Check breaker at electrical panel.
• Replace jet pump if necessary.
• Reset jet pump as described in System Start-up (p. 17).
• Check bladder tank.
• Replace jet pump and/or bladder tank as necessary.
• Clear sediment strainers on faucets.
• Clear pump inlet screen/water injector.
• Replace pump if necessary.
• Check fuses in control panel.
• Replace timer if necessary.
• Replace blower if necessary.
• Check On/Off float for proper operation.
• Check Timer Settings.
• Replace Timer Relay if necessary.
• Install water hammer suppressor or loop of flexible hose in pump inlet line.
• Shorten the length of pipe between the well pressure tank and the system.
• Bladder tank may be ruptured. Replace if necessary.
• Check pressure switch on pump for proper operation.
• Call for support.
• Check On/Off float for proper operation. Replace if necessary.
• Check sediment strainer and/or filter (if applicable) and clean if necessary.
• Install a flow restrictor or meter down the ball valve until the AIRaider
TM
outflow is 1 GPM or more less than the water flow entering the system.
TROUBLE SHOOTING
1
2
3
4
5