Page 18 of 22
IN052 Rev. K 0613
5. TROUBLE SHOOTING
Symptom
Solution
No water in house
•
Check power: switch in on position; circuit breaker at panel in on position.
•
Bypass System. If there is still no water, main well pump may not be functioning.
•
Check float switches including pump float for proper operation. Replace if necessary.
System running dry
•
Check sediment strainer and/or filter (if applicable) and clean if necessary.
•
Install a flow restrictor or meter down the ball valve until the AIRaider™ outflow is
less than the water flow entering the system by 1 GPM or more.
Water not entering
system
•
Check solenoids for proper operation. Replace if necessary.
•
Check float switches for proper operation. Replace if necessary.
•
Check sediment strainer and/or filter (if applicable) and clean if necessary.
Pump not functioning
•
Make sure red thermal bypass light is not illuminated.
•
Check power: switch in on position; circuit breaker at panel in on position.
•
Check pump float switch for proper operation.
•
Check that the pump priming orifice, rear left behind pump, is not blocked.
•
Replace pump if necessary.
Low water at faucets
•
Clear sediment strainers on faucets.
•
Clear pump inlet screen.
•
Replace pump if necessary.
Loud banging when
solenoids shut
•
Install additional water hammer suppressor or loop of flexible hose in pump inlet line.
•
Shorten the length of pipe between the well pressure tank and the system.
Solenoids chatter
when closing
•
Check On/Off float for proper operation. Replace if necessary.
Blower does not stop
running
•
Check On/Off float for proper operation.
Pump is short cycling
•
Check bladder tank if installed
•
Add bladder tank to house water line.
•
Inspect check valve for possible crack.
•
Check that bladder tank is correctly installed on the rise leg of the outlet tee with no
elbows or restrictions between tee and tank.
Blower does not run
•
Check blower fuse.
•
Check blower brushes
TROUBLE SHOOTING
1
2
3
4
5