2.4  OPERATION CHECKS 
 
____ Verify all connections are tight and leak-free.  
 
____ Insure the GP500 and all ducting is secure and vibration-free. 
 
____ Verify system vacuum pressure with Manometer or other pressure gauge. Insure 
vacuum pressure is less than 3.8" WC (based on sea-level operation, at higher 
altitudes reduce by about 4% per 1000 Feet). If this is exceeded, increase the 
number of suction points. 
 
____ Verify Radon levels by testing to EPA protocol. 
 
  
ADDENDUM 
 
PRODUCT SPECIFICATIONS 
 
The following chart shows fan performance for the GP500: 

 

 

                 Typical CFM vs Static Suction WC 

 

1.0" 

1.5" 

2.0" 

2.5" 

3.0" 

3.5" 

4.0" 

GP500 

88 

80 

74 

65 

54 

28 

14 

 

Power: 70 - 130 watts (varies with actual load conditions) @ 115 VAC 
Inlet/Outlet: 3" PVC 
Mounting: Brackets for vertical mount on bandjoist or sidewall.          
(16" Mounting Centers) 
Outdoor installations - GP500 mounts flush to wall projecting only 4" with inlet 
duct passing through the sidewall or band joist.  Power cord is on the inside 
simplifying connection. 
Weight: 20 lbs. 
Recommended ducting: 3" Schedule 20/40 PVC Pipe or attractive thin walled 3" O.D. 
PVC Downspout available from RadonAway 
Storage temperature range: 32 - 100 degrees F. 
Thermally protected 
Size: 17" x 12" x 4" (plus 7" inlet duct) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

Summary of Contents for GP500

Page 1: ...Page 1 of 8 IN006 Rev G ...

Page 2: ...tion of this device may affect the combustion airflow needed for safe operation of fuel burning equipment Check for possible backdraft conditions on all combustion devices after installation 5 NOTICE There are no user serviceable parts located inside the fan unit Do NOT attempt to open Return unit to the factory for service 6 All wiring must be performed in accordance with the National Fire Protec...

Page 3: ...re the temperature is never less than 32 degrees F or more than 100 degrees F When the unit is turned off for extended periods of time the drain plug should be removed from the bottom of the unit 1 3 ACOUSTICS The GP500 when installed properly operates with little or no noticeable noise to the building occupants Insure a solid mounting for the GP500 to avoid structure borne vibration or noise The ...

Page 4: ... possible the condensate drain tube may be extended to the point of drop off by slipping 5 16 ID tubing available from RadonAway over the drain tube Figure 1 An alternative condensation drain may be provided using the 3 8 NPT fitting on the bottom of the unit The alternative drain system must account for Radon leakage as the drain is under positive pressure If the unit is installed and electrical ...

Page 5: ...TALLATION 2 1 A C POWER CONNECTION The GP500 requires an 18 gauge 3 wire SJ power cord RadonAway p n 27003 or equivalent For proper seal the cord diameter should be 5 16 To install 1 Prepare the power cord by stripping jacket and insulation as shown in Figure 2 2 Loosen sealing nut on electrical inlet by turning counterclockwise 3 Insert power cord and route as shown in Figure 3 4 Fasten power cor...

Page 6: ...crews provided Use nylon washers provided under the screw heads to prevent marring the finish 8 Complete piping run providing flexible couplings or other means of disconnect for servicing the unit Under certain circumstances a flexible pipe coupling RadonAway p n 79019 1 may ease installation This may be particularly true of gable side installations where the system piping runs perpendicular to th...

Page 7: ... following chart shows fan performance for the GP500 Typical CFM vs Static Suction WC 1 0 1 5 2 0 2 5 3 0 3 5 4 0 GP500 88 80 74 65 54 28 14 Power 70 130 watts varies with actual load conditions 115 VAC Inlet Outlet 3 PVC Mounting Brackets for vertical mount on bandjoist or sidewall 16 Mounting Centers Outdoor installations GP500 mounts flush to wall projecting only 4 with inlet duct passing throu...

Page 8: ... This Warranty is contingent on installation of the Fan in accordance with the instructions provided This Warranty does not apply where any repairs or alterations have been made or attempted by others or if the unit has been abused or misused Warranty does not include damage in shipment unless the damage is due to the negligence of RadonAway RadonAway is not responsible for installation removal or...

Reviews: