background image

 

 

Manual 

 Wifi module 

for  a  software  update  can  be  deactivated  via  the  following 
command: your-module-IP/?autoupdate=0 

If  you  use  the  server  based  WLAN  configuration  page  (gear 
icon), the current module settings are transmitted to a script 
of the Bayernluft server for generating a comfortable settings 
page. A storage of this data does not take place. The privacy 
policy  of  our  homepage  applies,  which  you  can  view  at 
www.bayernluft.de/datenschutz. Please note that the module 
does not have its own SSL encryption certificate. We therefore 
recommend that you choose  the  device  name in such a way 
that no conclusions can be drawn about your identity. If you 
use  the  automatic  atomic  time  synchronization,  the  module 
retrieves  the  time  at  one  of  the  following  addresses: 
ptbtime1.ptb.de,  ptbtime2.ptb.de  or  ptbtime3.ptb.de  The 
data  protection  conditions  of  the  Physikalisch-Technische 
Bundesanstalt (PTB) www.ptb.de apply. 

 4

 

Static charge

 

The module is not overly sensitive to static charging. 
Nevertheless, we recommend that you discharge any charge 
on your body by touching a grounded object, e.g. water tap, 
radiator or similar, before unpacking the plug-on module. 

 

Summary of Contents for 58-202

Page 1: ...Wifi module Manual January 2021 ...

Page 2: ...RadonTec GmbH Hauptstraße 5 89426 Wittislingen Germany Tel 49 9076 919 98 35 E Mail info radontec de Website radontec de Shop radonshop com Version 01 1 25 01 2020 ...

Page 3: ...mpatible board 8 5 3 Connection with W LAN repeater 8 6 Firmware update 9 6 1 Version info 9 6 2 Manuals Update 10 6 3 Automatic update 10 7 Tips and troubleshooting 11 7 1 Login without WPS 11 7 2 Device does not respond in tool mode 11 8 Maintenance and care 12 9 Warranty 12 10 Support and Contact 13 10 1 Troubleshooting FAQ 13 10 2 Contact Us 13 ...

Page 4: ... Wifi module is the perfect complement to your AlphaAir Freshbox 25 2 Technical Data Frequency 2 4 GHz Standard IEEE 802 11b g n Power consumption Power On 1 2 Watt Continuous operation from 10 sec after Power On 0 8 0 9 Watt Safety WPA WPA2 ...

Page 5: ...connection has been successfully established and can be displayed there by entering the so called MAC address of the module For this reason the MAC address is then also transmitted to the Bayernluft server The MAC addresses are not linked by Bayernluft with the buyer of a WLAN module so that it is exclusively an anonymous MAC address If you do not actively communicate your MAC address to us Bayern...

Page 6: ...es not have its own SSL encryption certificate We therefore recommend that you choose the device name in such a way that no conclusions can be drawn about your identity If you use the automatic atomic time synchronization the module retrieves the time at one of the following addresses ptbtime1 ptb de ptbtime2 ptb de or ptbtime3 ptb de The data protection conditions of the Physikalisch Technische B...

Page 7: ...ion of the Wifi module For the first contact we recommend to set the right DIP switch label 1 down to HTML mode pos ON as shown in the video As soon as you then enter the MAC address of the module on our above mentioned web address after WPS pairing you can immediately click on the IP address and test the connection to the device To establish contact via Windows tool to the module please slide the...

Page 8: ...ight up properly after plugging it in but e g only glows please request a free replacement board from us On the product page of the WLAN module you can see a comparison photo of the voltage regulators 5 3 Connection with W LAN repeater Depending on the repeater manufacturer and model you may have to trigger WPS pairing either at the router e g FritzBox or directly at the next repeater Some routers...

Page 9: ...irmware at the bottom right of the HTML mode live screen The first number gives information about the signal strength to the access point 60 dBm are better than 80dBm It follows the firmware version of the device motherboard Attention this must be min 1838000A The version of the WLAN module follows ...

Page 10: ...mode for this Please replace the IP address in the following example with your own module address 192 168 0 100 updatecheck 1 The update may not yet be confirmed by a message page After about 1 minute you can reach the module again via its IP address and see the new version number in the bottom right corner if an update was available 6 3 Automatic update The automatic update can be activated or de...

Page 11: ...lf as an access point and how to store the access data 7 2 Device does not respond in tool mode Some support calls reached us because the connection setup via our Windows tool did not work These were the two most common causes a The right dip switch on the module was not switched up to tool mode This switch is used to toggle between HTML tool mode Currently both modes cannot be operated in paralle...

Page 12: ...workmanship under normal use for a period of one year after receipt of the product Contamination due to dirt or improper use is not covered by the warranty During the warranty period the product will be repaired or replaced at no charge Exclusions This warranty does not cover damage caused by abuse neglect or misuse This includes damage caused by drops impacts or penetrations It is also void if th...

Page 13: ...questions on our website https www radontec de 10 2 Contact Us Should you have any further questions or require further help and technical support please do not hesitate to contact us RadonTec GmbH Hauptstraße 5 89426 Wittislingen Germany Tel 49 9076 919 98 35 E Mail info radontec de Website radontec de Shop radonshop com ...

Reviews: