20
Manual
–
AlphaBlower EX 100/ 125
•
Install ventilation lines properly.
•
Lay the mains cable firmly to the installation site.
•
It is essential to observe the relevant regulations for
electrical installation and device assembly, in Germany in
particular DIN VDE 0100 with the corresponding parts.
•
To avoid vibration transmission to the pipe system, use
elastic fastening collars (type ELR).
•
To avoid leakage, only screw the roof base onto a suitable,
level substructure. For direct mounting of the
AlphaBlower EX on the ventilation duct, dismantle the
roof base (3 self-tapping screws).
•
Use suitable insulation, soundproofing and installation
material between the unit and the roof base.
10.1
Fan installation
Risk of injury in case of wrong mounting location or
insufficient fastening with the roof or the piping.
1.
Only mount the unit at locations with sufficient load-
bearing capacity.
2.
Sufficiently dimensioned fastening material must be
provided by the customer (screws with Ø 10 mm, min.
strength class 8.8).
3.
Screw the unit tightly to the roof, roof base or pipework.