SCOPIA 400/1000 Gateway User Guide
Configuring Port Settings
6
In the Select the channels field, define individual channels you want to
use for fractional E1 or T1 distribution. The table contains 24 check
boxes for T1 or 31 check boxes for E1.
Note
You cannot select channel 24 of the T1 settings and channel 16 of the
E1 settings. These are reserved as the signaling (D) channels that are essential
for communication.
Note
Click
Select All
to select all fractional channels or
Deselect All
to
deselect all fractional channels.
7
Click
OK
to close the Fractional dialog box.
C
ONFIGURING
L
INE
C
ODING
, F
RAMING
AND
S
IGNALING
T
YPE
In the Physical Interface section of the PRI Port tabs, you can configure coding,
framing, and signaling type settings as part of the physical line properties of the
specified PRI port.
Procedure
1
In the Gateway interface, on the sidebar, click
Gateway
(if not already
selected).
2
Click the applicable PRI Port tab.
3
Click
Physical Interface
.
4
Click
Advanced
to configure line coding, framing, and signaling type.
The Advanced dialog box appears.
5
In the Line coding field, choose the type of modulation used to encode
the data.
6
In the Framing field, choose the framing and error detection method.
Note
The ESF CRC6JT framing option is available only if you select
Japan
in the Country field and
Long Haul
in the Line Build Out
field.
Summary of Contents for SCOPIA 400
Page 1: ...SCOPIA 400 1000 Gateway version 5 6 User Guide...
Page 10: ......
Page 70: ...60 SCOPIA 400 1000 Gateway User Guide Registering the Online Help...
Page 166: ...156 SCOPIA 400 1000 Gateway User Guide Importing Configuration Files...
Page 198: ...188 SCOPIA 400 1000 Gateway User Guide Using Express Setup...
Page 202: ...192 SCOPIA 400 1000 Gateway User Guide Upgrading Software...