144
SCOPIA 400/1000 Gateway User Guide
Configuring Port Settings
Procedure
1
In the Network Specific Facility (NSF) field, choose
Custom
.
2
Click
Configure
.
The NSF Configuration dialog box appears. You can configure up to four
NSF information elements.
Note
You can only configure the NSF information elements (NSF IEs) if
you set the Interface field in the Physical Interface section of the PRI Port tabs
to
T1
and set the Country field to
US
. All outgoing Q.931 setup messages will
contain the NSF IE.
Table 3-27
Pre-configured NSF Settings
Pre-configured Setting
Information Element (IE) Octets
IE 1 Octets
IE 2 Octets
3
3.1
3.2
3.2
3.2
4
3
4
5
AT&T Accunet
4
A1
32
38
38
E6
AT&T Megacom
4
A1
32
38
38
E3
AT&T Megacom 800
4
A1
32
38
38
E2
AT&T SDDN
4
A1
32
38
38
E1
AT&T A SDVG
4
A1
32
38
38
E6
0
49
0F
AT&T M SDVG
4
A1
32
38
38
E3
0
49
0F
AT&T Megacom 800 + SDVG
4
A1
32
38
38
E2
0
49
0F
AT&T SDDN + SDVG
4
A1
32
38
38
E1
0
49
0F
MCI VNET
4
A9
32
32
32
E1
Sprint VPN
4
A9
33
33
33
E1
Summary of Contents for SCOPIA 400
Page 1: ...SCOPIA 400 1000 Gateway version 5 6 User Guide...
Page 10: ......
Page 70: ...60 SCOPIA 400 1000 Gateway User Guide Registering the Online Help...
Page 166: ...156 SCOPIA 400 1000 Gateway User Guide Importing Configuration Files...
Page 198: ...188 SCOPIA 400 1000 Gateway User Guide Using Express Setup...
Page 202: ...192 SCOPIA 400 1000 Gateway User Guide Upgrading Software...