Installing the SCOPIA Gateway
31
Installing the Gateway
I
NSTALLING
THE
G
ATEWAY
M
ODULE
This section describes how to install the SCOPIA Gateway module in the
SCOPIA 400 chassis and in the SCOPIA 1000 chassis.
Warning
You must install the RTM module before you install the Gateway
module. Inserting an RTM module in the rear of the chassis when a Gateway
module is already installed in the same position at the front of the chassis may
damage the chassis.
Procedure
1
On the front of the chassis, loosen the screws of the blank
panel covering the slot into which the Gateway module is to be
installed.
2
Remove the blank panel.
3
Remove the new Gateway module from the antistatic bag.
4
Press the red buttons and open the handles of the Gateway
module.
5
Align the edges of the Gateway module with the chassis guide
rails.
6
Slide the Gateway module into the chassis until it stops (see
Figure 2-5
for the SCOPIA 400 chassis).
7
Use even pressure to push the module further into the slot.
Caution
Do not force the connection. Forcing the connection can bend or
damage the pins in the connector inside the chassis.
Note
If you are installing the Gateway module and the power to the chassis
is on, the SWAP RDY LED on the module front panel turns blue when you
slide the module into the chassis as far as it will go. This means that you can
secure the module safely. The LED turns off when the handles are closed.
Summary of Contents for SCOPIA 400
Page 1: ...SCOPIA 400 1000 Gateway version 5 6 User Guide...
Page 10: ......
Page 70: ...60 SCOPIA 400 1000 Gateway User Guide Registering the Online Help...
Page 166: ...156 SCOPIA 400 1000 Gateway User Guide Importing Configuration Files...
Page 198: ...188 SCOPIA 400 1000 Gateway User Guide Using Express Setup...
Page 202: ...192 SCOPIA 400 1000 Gateway User Guide Upgrading Software...