5.3. USER MENU
Menu is divided into 9 basic function groups. Each group has an individual name starting with
a capital letter,
P
.
P1 ADJUSTMENT
P1.1
INT. CALIB.
|
[internal adjustment]
P1.2
EXT. CALIB.
|
[external adjustment]
P1.3
USER CALIBRATION
|
[user adjustment]
P1.4
CALIBRATION TEST
|
[adjustment test]
P1.5
AUTO. CALIB.
|
[automatic adjustment]
P1.6
AUTO. CALIB. C.
|
[time of automatic adjustment]
P2 WORKING MODES
P2.1
ACCESSIBILITY
|
[settings for the accessibility of individual modes
while working with the balance]
P2.2
WEIGHING
|
[setting for the function weighing]
P2.3
COUNTING PCS
|
[settings for the function counting pieces]
P2.4
CHECKWEIGHING
|
[settings for the function checkweighing]
P2.5
DOSING
|
[settings for the function dosing]
P2.6
DEVIATIONS
|
[settings for the function deviations % against
the mass of the standard]
P2.7
DENS. OF SOLIDS
|
[settings for determining density of solids]
P2.8
DENS OF LIQUIDS
|
[settings for determining density of liquids]
P2.9
ANIMAL WEIGHING
|
[settings for the function animal weighing]
P2.10
STATISTICS
|
[settings for the function statistics]
P2.11
TOTALISING
|
[settings for the function totalising]
P2.12
PEAK HOLD
|
[settings for the function peak hold]
P2.13
PIPETTES CALIB.
|
[settings for the function pipettes calibration]
P3 COMMUNICATION
P3.1
COM1
|
[transmission parameters port COM 1]
P3.2
COM2
|
[transmission parameters port COM 2]
P3.3
WIFI
|
[transmission parameters port WIFI]
P4 DEVICES
P4.1
COMPUTER
|
[
PC connection port
]
P4.2
PRINTER
|
[printer connection port]
P4.3
BARCODE READER
|
[barcode connection port]
P4.4
ADD.DISPLAY
|
[additional display port]
P4.5
EXT.BUTTONS
|
P5 PRINTOUT
P5.1
CAL. REPORT
|
[contents of the adjustment report]
P5.2
HEADER
|
[contents of the header printout]
P5.3
GLP PRNT.
|
[contents of the weighing result prnt.]
P5.4
FOOTER
|
[contents of the footer printout]
P5.5
NSD.PRN.1
|
[project of non-standard printout 1]
P5.6
NSD.PRN.2
|
[project of non-standard printout 2]
P5.7
NSD.PRN.3
|
[project of non-standard printout 3]