background image

 

3

 

 

SAFETY MEASURES AND PRECAUTIONS

 

 

Before  you  start  installing,  using  or  maintaining  the  device,  you  are  obligated  
to get familiar with this operating manual and follow its guidelines.

 

 

 

Before  use,  please  read  this  Operating  Manual  carefully  and  use  
the device as per its intended use.

 

 

Put loads in the central part of the weighing pan.

 

 

Load  the  weighing  pan  with  goods  whose  gross  mass  is  lower  than  the 
maximum loading capacity of the scale.

 

 

Do not leave large loads on the weighing pan for a long time.

 

 

Secure  the  device  against  excessive  temperature  fluctuations,  solar 
radiation and UV radiation, substances that cause chemical reactions.

 

 

The device must not be used in explosive atmospheres (gas or dust).

 

 

Do  not  use  sharp  tools  (e.g.  knife,  screwdriver,  etc.)  to  use  the  touch 
panel.

 

 

In case of failures, unplug the device immediately.

 

 

The  device  that  is  to  be  withdrawn  from  service  must  be  disposed  of  in 
accordance with applicable rules of law.

 

 

If  the  device  is  to  operate  in  the  bothersome  electrostatic  environment  
(e.g.  printing  house,  packhouse,  etc.),  an  earthing  cable  must  be 
connected.  To  do  so,  use  a  functional  earthing  terminal  in  the  device, 

marked as 

.

 

 

Wi-Fi

®

 is a registered trademark owned by Wi-Fi Alliance. This trademark 

has been  used  is  this  document  for  reference  only  and  is not  intended  to 
mark compliance of any products with products certified by Wi-Fi Alliance.

 

Summary of Contents for CY10

Page 1: ...CY10 MULTIFUNCTIONAL SCALES OPERATING MANUAL ITKU 134 01 02 23 EN...

Page 2: ...2 FEBRUARY 2023...

Page 3: ...V radiation substances that cause chemical reactions The device must not be used in explosive atmospheres gas or dust Do not use sharp tools e g knife screwdriver etc to use the touch panel In case of...

Page 4: ...5 DISPOSAL 7 6 STRUCTURE 7 6 1 Dimensions 8 6 2 Description of Connectors 10 7 INSTALLATION 11 7 1 Unpacking and Assembly 11 7 1 1 CY10 D2 Series Scales 11 7 1 2 CY10 xx K Series Scales 12 7 2 Scale L...

Page 5: ...presentatives of the manufacturer and user C RADWAG shall not be held responsible for defects or losses deriving from unauthorized or improper production or servicing D The guarantee does not cover th...

Page 6: ...parations Always remove dirt with a microfiber cloth so that protective coatings of the elements cannot be damaged In case of daily care and stain removal follow the steps below 1 Remove dirt with a c...

Page 7: ...the scope and method of repair The operator is not allowed to repair the product in any way Any unauthorized manipulations modifications repairs etc shall invalidate certificates declarations and guar...

Page 8: ...8 Single sensor scale components general view Single sensor scale components general view 1 Weighing pan 2 Star piece 3 Mass sensor 4 Foundation 6 1 Dimensions CY10 D2 scales dimensions...

Page 9: ...9 CY10 F1 K scales dimensions CY10 C2 K scales dimensions...

Page 10: ...10 CY10 C3 K scales dimensions 6 2 Description of Connectors 1 Reboot or on off button 2 Left loudspeaker 3 Right loudspeaker 4 USB type A port 5 USB type A port...

Page 11: ...tive sensors 15 Camera 16 Camera LED light 17 Signal LED light 18 Weighing platform cable glands 7 INSTALLATION 7 1 Unpacking and Assembly 7 1 1 CY10 D2 Series Scales A Remove the scale from the facto...

Page 12: ...the feeder cable into the mains socket and put the feeder cable plug into the port at the back of the weighing indicator housing The operating system and RADWAG software loading procedure will initiat...

Page 13: ...will restart and device will reload 8 HOME PAGE The home page can be divided into 5 fields The upper part of the screen shows information on current working mode logged user date time active connectio...

Page 14: ...software manual At the bottom of the screen you can see permanent functional buttons 9 NAVIGATION IN THE MENU Navigation in the menu is intuitive and user friendly Thanks to the touch screen display i...

Page 15: ...r going back to the home screen Procedure Press button a couple of times to make the scale return to home screen Press in the lower bar to return to home page immediately 10 WEIGHING Load the weighing...

Page 16: ...ing pan Avoid side loads of the scale particularly side strokes 11 CONNECTION WIRE DIAGRAMS Scale computer wire RS232 Scale printer wire RADWAG ZEBRA To assure correct cooperation with peripherals wit...

Page 17: ...rnet wire is a standard network cable that ends on both sides with RJ45 tip 12 TECHNICAL PARAMETERS Technical parameters of particular scales are available on the following website www radwag pl 13 ER...

Page 18: ...18...