background image

 

3

 

PRECAUTIONS 

 

Prior installing, using or maintaining the frame it is necessary to read  
ITKU-101-02-12-18-EN user manual. Use the device only as intended. 

 

The above user manual must be at a reach of the operator's hand in the course 
of device operation. 

 

 

Symbol marking sections that are extremely important for protection 
against explosion. 

 

The device must be applied in accordance with the intended use only. 

 

Prior installation of the frame and start, it is necessary to analyse 
whether the device complies with the usage requirements regarding 
particular hazardous area. 

 

In case of any sign of damage, it is necessary to stop using the device 
immediately. The damaged component must be replaced or repaired 
by RADWAG service immediately. 

 

While installing the device, it is necessary to follow strictly this service 
manual requirements. Not adhering to the requirements results with 
loss of explosion safety. 

 

The frame may be used as a component of device/set intended  
for operation in hazardous area. Manufacturer of such device/set  
is obliged to carry out analysis of the complete device/set in order  
to confirm compliance with standards. 

 

The frame must be connected to the same equalizing circuit as the 
scale.   

 

Do not apply protection shields. 

 

Technical condition of the frame must be tested and inspected by 
trained personnel, in accordance with this user manual, at least once 
every three months, and in accordance with this user manual.   

Summary of Contents for HX5.EX

Page 1: ...HX5 EX 4 Load Cell Scales with EX Frame FRAME ASSEMBLY MANUAL ITKM 003 01 08 19 EN...

Page 2: ...2 AUGUST 2019...

Page 3: ...to stop using the device immediately The damaged component must be replaced or repaired by RADWAG service immediately While installing the device it is necessary to follow strictly this service manual...

Page 4: ...4 CONTENTS 1 INTENDED USE 5 2 FRAME ASSEMBLY 6 3 WARRANTY CONDITIONS 8 4 SECURITY REQUIREMENTS 9...

Page 5: ...as explosion group IIB and IIA and as temperature class T1 T2 T3 T4 frames made of stainless steel can be used in zones 1 and 2 where there is a risk of explosion due to mixture of air with vapour mis...

Page 6: ...inimum Prepare recess for the frame The recess must be compliant with the requirements of zones 1 and 2 of hazardous area If there is a risk of an explosive atmosphere occurrence due to mixture of air...

Page 7: ...zardous area recess for the scale In order to prevent electrostatic charges accumulation it is necessary to connect the frame the platform and the indicator to the same equalizing circuit Spots marked...

Page 8: ...epresentatives C RADWAG does not bear any responsibility for damage or losses resulting from misuse or unauthorized use or servicing D The warranty does not cover mechanical damage caused by product e...

Page 9: ...on in dust atmospheres Diagram with areas of operation is presented in the first section of this service manual Explosion safety of ramps is ensured by Making frame mechanical design in accordance wit...

Page 10: ...10...