4.3.  ECR Recorder and THB.R Set 

 

In order to run the ECR recorder, connect it to the computer, next connect the THB.R module 
to the recorder.  
On your computer install the 

THB-R-Multi

 software enabling readout of measured quantities 

values, next set communication parameters. In order to do it correctly, follow instructions 
provided in user manual of the balance. 
The ECR cooperates with THB.R (see the figure below). It records air temperature, 
atmospheric pressure and air humidity values read from connected THB.R modules. The 
ECR can record values from 2 THB.R modules simultaneously. 
By standard the set comprises one THB.R module. 
 

 

 
The ECR recorder enables readout of metrological data simultaneously from all the 
connected modules within a specified time interval. The data is saved to the recorder's 
internal memory. 
The recorder is powered by an external 10-20VDC power supply, or USB interface. 
Additionally it features an internal battery. The battery is charged when the ECR recorder is 
connected to a PC using USB port (e.g. during readout of the data from the recorder's 
internal memory), and when operating with use of external power supply. 
RS232 and USB interfaces enable connecting the recorder to a PC with installed 

THB-Multi

 

software, which software allows preview and readout of the parameters saved to the 
recorder. 
 
Set components: 
- ECR recorder, 
- THB.R module - 1 pcs., 
- TH-W2 water temperature sensor, 
- Power supply 12V, 
- USB B cable 
- RS232 cable 

THB-R-Multi

 software, and 

- additional THB.R module, 

on purchase order

Summary of Contents for THB.Y

Page 1: ...THB Ambient Conditions Module IMMU 49 01 10 17 EN USER MANUAL THB Y THB X THB PC THB R www radwag com...

Page 2: ...2 OCTOBER 2017...

Page 3: ...2 THB MODULE DESIGN 4 3 UNPACKING 5 3 1 Unpacking 5 4 START UP 6 4 1 THB Y and THB X Modules 6 4 2 THB PC Modules 8 4 3 ECR Recorder and THB R Set 9 5 MAINTENANCE SERVICE RECYCLING 10 5 1 Maintenance...

Page 4: ...f measurement values transferred from the THB module the 3Y 4Y X2 balance program determines air density The determined air density is displayed on the screen too THB PC module PC version is operated...

Page 5: ...B B connector recorder computer connection via standard USB cable d PS2 connector for connection of liquid aspirator weighing table for pipettes calibration e 2 x PS2 connector for connection of THB R...

Page 6: ...et communication parameters THB Y THB Y has been designed to enable measurement of ambient conditions It cooperates with laboratory balances of 3Y and 4Y series It is connected directly to COM 2 port...

Page 7: ...It cooperates with laboratory balances of X2 series It is connected directly to either COM 1 or COM 2 port of the balance THB X allows to measure air temperature atmospheric pressure air humidity Set...

Page 8: ...ns provided in user manual of the balance THB PC THB PC has been designed to enable measurement of ambient conditions It is connected directly to a computer port via RS232 Additionally it is necessary...

Page 9: ...eadout of metrological data simultaneously from all the connected modules within a specified time interval The data is saved to the recorder s internal memory The recorder is powered by an external 10...

Page 10: ...1 Maintenance Power supply housing and sensors shield can be cleaned using cloth soaked with alcohol based substance 5 2 Service Only authorized RADWAG service points are allowed to disassembly repair...

Page 11: ...11...

Reviews: