PRECAUTIONS 

 

Prior  to  installation,  use  or  maintenance  activities,  carefully  read  this  user 
manual and follow the provided guidelines. 

 

 

Prior  to  the  first  use,  carefully  read  this  user  manual.  Use  the  weighing 
device only as intended. 

 

Place weighed loads in the centre of the weighing pan. 

 

Load the weighing pan with loads of gross weight which does not exceed 
the maximum capacity. 

 

Mind  not  to  leave  heavy  loads  on  the  weighing  pan  for  longer  periods  
of time. 

 

Protect the indicator against considerable temperature variation, solar and 
UV radiation, substances causing chemical reactions. 

 

The C32 scale must not be operated in hazardous areas endangered with 
explosion of gases, and in dusty environments. 

 

In case of damage, immediately unplug the device from the mains. 

 

Scales  to  be  decommissioned  must  be  decommissioned  in  accordance 
with valid legal regulations. 

 

Do  not  let  battery  discharge  in  case  of  prolonged  storage  of  the  device  
in low temperature. 

 

Accumulators  do  not  belong  to  regular  household  waste.  The  European 
legislation requires discharged accumulators to be collected and disposed 
separately  from  other  communal  waste  with  the  aim  of  being  recycled. 
Symbols  on  batteries  identify  harmful  compounds:  Pb  =  lead,  
Cd = cadmium, Hg = mercury. Dear user, you are obliged to dispose of the 
worn out batteries as regulated. 

 

If  the  scale  is  to  be  operated  in  conditions  that  are  difficult  due  to 
electrostatics (e.g. printing house, packing centre, etc.), you must connect 
it to the earth wire. To enable this, the device features functional earthing 

terminal, marked with 

 symbol. 

Summary of Contents for WLC

Page 1: ......

Page 2: ...2 APRIL 2021...

Page 3: ...dusty environments In case of damage immediately unplug the device from the mains Scales to be decommissioned must be decommissioned in accordance with valid legal regulations Do not let battery disch...

Page 4: ...7 5 RECYCLING 8 6 MECHANICAL DESIGN 8 6 1 Dimensions 8 6 2 Connectors Arrangement 9 6 3 Pins Overview 10 6 4 Operation panel 10 7 INSTALLATION 11 7 1 Unpacking and Installation 11 7 2 Levelling 11 7 3...

Page 5: ...om unauthorized or inadequate performing of production or service processes D The warranty does not cover mechanical damage caused by product exploitation other than intended damage of thermal and che...

Page 6: ...lic solvent sodium carbonate to remove BASE use protogenic solvent mineral acid of various concentration In case of heavy contamination use brush and detergent nevertheless avoid detergents containing...

Page 7: ...brasive substances Avoid using hard brush this may cause scratches It is recommended to use microfibre cloth While polishing the surface use circular movements Use clean dry cloth to make the surface...

Page 8: ...they are not to be treated as a regular household waste Scales to be decommissioned must be decommissioned in accordance with valid legal regulations 6 MECHANICAL DESIGN 6 1 Dimensions Dimensions of W...

Page 9: ...9 Dimensions of WLC C2 K scale Dimensions of WLC C2 R scale 6 2 Connectors Arrangement 1 power supply socket 2 RS232 1 connector 3 weighing platform cable inlet 4 RS232 2 connector option...

Page 10: ...D Pin4 5VDC Pin5 GND RS232 2 connector DB9 M male 6 4 Operation panel Keys Press to switch the weighing device on off hold the key for about 1 second Function key press to change the working mode Pres...

Page 11: ...g and Installation Unpack the device and place it on a flat and even surface Keep it far away from any sources of heat Remove transport lock WLC F1 WLC C2 Scales Install the weighing pan follow the be...

Page 12: ...ext displayed reading unit is conditioned by scale type In case the weighing result is not zero after indication stabilisation press key 7 4 Warm Up Time For correct scale operation the workroom tempe...

Page 13: ...nation Depending on the battery state a respective status is displayed on the screen for 2s 80 Battery power supply Battery power given in CHArGE Battery charge in progress The device is connected to...

Page 14: ...ome screen To return to the home screen press key repeatedly 9 WEIGHING Load the weighing pan Read the result when stability marker is displayed To assure long term operation and correct mass measurem...

Page 15: ...g in particular side shocks 10 DIAGRAMS OF CONNECTION CABLES scale computer cable scale printer cable EPSON 11 TECHNICAL SPECIFICATIONS For technical specifications of respective scales go to RADWAG w...

Page 16: ...transmission Enter P5 ducE 5 1 PC submenu and set correct 5 1 3 Int parameter value No printout on a scale connected printer Incorrect printer port set in 5 2 1 Prt parameter Enter P5 ducE 5 2 Prtr s...

Page 17: ...art mass error indication out of range 10 of start mass H i Display range of total mass on scale display exceeded in Totalizing mode u L o Too low battery charge The scale is about to shut down E r r...

Page 18: ...18...

Reviews: